Analytical applications of aptamers S Tombelli, M Minunni, M Mascini Biosensors and Bioelectronics 20 (12), 2424-2434, 2005 | 1247 | 2005 |
Surface plasmon resonance imaging for affinity-based biosensors S Scarano, M Mascini, APF Turner, M Minunni Biosensors and bioelectronics 25 (5), 957-966, 2010 | 489 | 2010 |
Aptamer-based detection of plasma proteins by an electrochemical assay coupled to magnetic beads S Centi, S Tombelli, M Minunni, M Mascini Analytical Chemistry 79 (4), 1466-1473, 2007 | 465 | 2007 |
Aptamers-based assays for diagnostics, environmental and food analysis S Tombelli, M Minunni, M Mascini Biomolecular engineering 24 (2), 191-200, 2007 | 341 | 2007 |
Aptamer-based biosensors for the detection of HIV-1 Tat protein S Tombelli, M Minunni, E Luzi, M Mascini Bioelectrochemistry 67 (2), 135-141, 2005 | 327 | 2005 |
Electrochemical and piezoelectric DNA biosensors for hybridisation detection F Lucarelli, S Tombelli, M Minunni, G Marrazza, M Mascini analytica chimica acta 609 (2), 139-159, 2008 | 326 | 2008 |
New trends in affinity sensing: aptamers for ligand binding E Luzi, M Minunni, S Tombelli, M Mascini TrAC Trends in Analytical Chemistry 22 (11), 810-818, 2003 | 302 | 2003 |
Quartz crystal microbalance (QCM) affinity biosensor for genetically modified organisms (GMOs) detection I Mannelli, M Minunni, S Tombelli, M Mascini Biosensors and bioelectronics 18 (2-3), 129-140, 2003 | 296 | 2003 |
Development of biosensors with aptamers as bio-recognition element: the case of HIV-1 Tat protein M Minunni, S Tombelli, A Gullotto, E Luzi, M Mascini Biosensors and Bioelectronics 20 (6), 1149-1156, 2004 | 251 | 2004 |
Surface plasmon resonance applications in clinical analysis S Mariani, M Minunni Analytical and bioanalytical chemistry 406, 2303-2323, 2014 | 226 | 2014 |
Analytical performances of aptamer-based sensing for thrombin detection A Bini, M Minunni, S Tombelli, S Centi, M Mascini Analytical chemistry 79 (7), 3016-3019, 2007 | 222 | 2007 |
Surface modifications for the development of piezoimmunosensors S Storri, T Santoni, M Minunni, M Mascini Biosensors and bioelectronics 13 (3-4), 347-357, 1998 | 211 | 1998 |
Detection of pesticide in drinking water using real-time biospecific interaction analysis (BIA) M Minunni, M Mascini Analytical Letters 26 (7), 1441-1460, 1993 | 196 | 1993 |
Surface plasmon resonance biosensor for genetically modified organisms detection E Mariotti, M Minunni, M Mascini Analytica chimica acta 453 (2), 165-172, 2002 | 168 | 2002 |
The quartz crystal microbalance as biosensor. A status report on its future M Minunni, M Mascini, GG Guilbault∗, B Hock Analytical letters 28 (5), 749-764, 1995 | 163 | 1995 |
Immobilisation of DNA probes for the development of SPR-based sensing R Wang, S Tombelli, M Minunni, MM Spiriti, M Mascini Biosensors and Bioelectronics 20 (5), 967-974, 2004 | 147 | 2004 |
Direct immobilisation of DNA probes for the development of affinity biosensors I Mannelli, M Minunni, S Tombelli, R Wang, MM Spiriti, M Mascini Bioelectrochemistry 66 (1-2), 129-138, 2005 | 140 | 2005 |
Comparison among differential pulse voltammetry, amperometric biosensor, and HPLC/DAD analysis for polyphenol determination A Romani, M Minunni, N Mulinacci, P Pinelli, FF Vincieri, M Del Carlo, ... Journal of Agricultural and Food Chemistry 48 (4), 1197-1203, 2000 | 137 | 2000 |
Self-powered microneedle-based biosensors for pain-free high-accuracy measurement of glycaemia in interstitial fluid LM Strambini, A Longo, S Scarano, T Prescimone, I Palchetti, M Minunni, ... Biosensors and Bioelectronics 66, 162-168, 2015 | 132 | 2015 |
Piezoelectric biosensors: strategies for coupling nucleic acids to piezoelectric devices S Tombelli, M Minunni, M Mascini Methods 37 (1), 48-56, 2005 | 126 | 2005 |