Follow
Robert Tozer
Robert Tozer
Director of Operational Intelligence Ltd / Visiting Professor at London South Bank University
Verified email at dc-oi.com - Homepage
Title
Cited by
Cited by
Year
A novel experimental investigation of a solar cooling system in Madrid
A Syed, M Izquierdo, P Rodriguez, G Maidment, J Missenden, A Lecuona, ...
International Journal of refrigeration 28 (6), 859-871, 2005
2762005
Combined cooling heat and power in supermarkets
GG Maidment, RM Tozer
Applied thermal engineering 22 (6), 653-665, 2002
1962002
Combined cooling heat and power in supermarkets
GG Maidment, RM Tozer
Applied thermal engineering 22 (6), 653-665, 2002
1912002
Using data centres for combined heating and cooling: An investigation for London
GF Davies, GG Maidment, RM Tozer
Applied Thermal Engineering 94, 296-304, 2016
1552016
The novel use of phase change materials in refrigeration plant. Part 1: Experimental investigation
F Wang, G Maidment, J Missenden, R Tozer
Applied Thermal Engineering 27 (17-18), 2893-2901, 2007
1382007
The novel use of phase change materials in refrigeration plant. Part 2: Dynamic simulation model for the combined system
F Wang, G Maidment, J Missenden, R Tozer
Applied Thermal Engineering 27 (17-18), 2902-2910, 2007
1022007
The novel use of phase change materials in refrigeration plant. Part 3: PCM for control and energy savings
F Wang, G Maidment, J Missenden, R Tozer
Applied Thermal Engineering 27 (17-18), 2911-2918, 2007
882007
Fundamental thermodynamics of ideal absorption cycles
RM Tozer, RW James
International journal of refrigeration 20 (2), 120-135, 1997
881997
Cool design data center
RM Tozer
US Patent 8,984,906, 2015
762015
Data Centers' Energy Auditing and Benchmarking-Progress Update.
M Salim, R Tozer
ASHRAE transactions 116 (1), 2010
702010
Cooling tower—an energy conservation resource
HR Goshayshi, JF Missenden, R Tozer
Applied Thermal Engineering 19 (11), 1223-1235, 1999
651999
Data centers
R Tozer, C Bash, C Patel
US Patent 7,903,404, 2011
512011
A review of research concerning the use of PCMs in air conditioning and refrigeration engineering
F Wang, G Maidment, J Missenden, R Tozer
Advances in building technology, 1273-1280, 2002
512002
Data center cooler with chiller and cooling tower
R Tozer
US Patent 9,179,580, 2015
422015
A novel special distributed method for dynamic refrigeration system simulation
FQ Wang, GG Maidment, JF Missenden, RM Tozer
International Journal of refrigeration 30 (5), 887-903, 2007
422007
Data center air management metrics-practical approach
R Tozer, M Salim
2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical …, 2010
402010
Air Management Metrics in Data Centers.
R Tozer, C Kurkjian, M Salim
ASHRAE transactions 115 (1), 2009
402009
Heat powered refrigeration cycles
R Tozer, RW James
Applied Thermal Engineering 18 (9-10), 731-743, 1998
391998
Extended temperature–entropy (T–s) diagrams for aqueous lithium bromide absorption refrigeration cycles
R Tozer, A Syed, G Maidment
International Journal of Refrigeration 28 (5), 689-697, 2005
352005
Best practice guidelines for the EU code of conduct on data centre energy efficiency
M Acton, P Bertoldi, J Booth, L Newcombe, A Rouyer, R Tozer
European union joint research centre, Luxembourg, 2018
332018
The system can't perform the operation now. Try again later.
Articles 1–20