Follow
Mitsue Miyazaki
Mitsue Miyazaki
Verified email at ucsd.edu
Title
Cited by
Cited by
Year
Nonenhanced MR Angiography1
M Miyazaki, VS Lee
Radiology 248 (1), 20-43, 2008
5062008
Non‐contrast‐enhanced MR angiography using 3D ECG‐synchronized half‐Fourier fast spin echo
M Miyazaki, S Sugiura, F Tateishi, H Wada, Y Kassai, H Abe
Journal of Magnetic Resonance Imaging 12 (5), 776-783, 2000
2332000
Non‐contrast enhanced MR angiography: physical principles
AJ Wheaton, M Miyazaki
Journal of magnetic resonance imaging 36 (2), 286-304, 2012
1992012
Peripheral MR angiography: separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-echo …
M Miyazaki, H Takai, S Sugiura, H Wada, R Kuwahara, J Urata
Radiology 227 (3), 890-896, 2003
1952003
Visualization of Cerebrospinal Fluid Movement with Spin Labeling at MR Imaging: Preliminary Results in Normal and Pathophysiologic Conditions1
S Yamada, M Miyazaki, H Kanazawa, M Higashi, Y Morohoshi, S Bluml, ...
Radiology 249 (2), 644-652, 2008
1912008
Non‐contrast enhanced MR angiography: Established techniques
M Miyazaki, M Akahane
Journal of magnetic resonance imaging 35 (1), 1-19, 2012
1892012
Influence of respiration on cerebrospinal fluid movement using magnetic resonance spin labeling
S Yamada, M Miyazaki, Y Yamashita, C Ouyang, M Yui, M Nakahashi, ...
Fluids and Barriers of the CNS 10, 1-7, 2013
1772013
Influence of respiration on cerebrospinal fluid movement using magnetic resonance spin labeling
S Yamada, M Miyazaki, Y Yamashita, C Ouyang, M Yui, M Nakahashi, ...
Fluids and Barriers of the CNS 10, 1-7, 2013
1772013
Pulmonary high‐resolution ultrashort TE MR imaging: Comparison with thin‐section standard‐and low‐dose computed tomography for the assessment of pulmonary parenchyma diseases
Y Ohno, H Koyama, T Yoshikawa, S Seki, D Takenaka, M Yui, A Lu, ...
Journal of Magnetic Resonance Imaging 43 (2), 512-532, 2016
1482016
Current and emerging MR imaging techniques for the diagnosis and management of CSF flow disorders: a review of phase-contrast and time–spatial labeling inversion pulse
S Yamada, K Tsuchiya, WG Bradley, M Law, ML Winkler, MT Borzage, ...
American journal of neuroradiology 36 (4), 623-630, 2015
1192015
Magnetic resonance imaging using preparation scan for optimizing pulse sequence
M Miyazaki, H Takai
US Patent 6,781,375, 2004
1012004
MR imaging providing tissue/blood contrast image
M Miyazaki
US Patent 7,254,437, 2007
90*2007
Thoracic duct: visualization at nonenhanced MR lymphography—initial experience
S Hayashi, M Miyazaki
Radiology 212 (2), 598-600, 1999
901999
Standard-, reduced-, and no-dose thin-section radiologic examinations: comparison of capability for nodule detection and nodule type assessment in patients suspected of having …
Y Ohno, H Koyama, T Yoshikawa, Y Kishida, S Seki, D Takenaka, M Yui, ...
Radiology 284 (2), 562-573, 2017
882017
Non-contrast-enhanced MR angiography of the abdomen
M Miyazaki, H Isoda
European journal of radiology 80 (1), 9-23, 2011
872011
Clinical feasibility of noncontrast-enhanced magnetic resonance lymphography of the thoracic duct
H Takahashi, S Kuboyama, H Abe, T Aoki, M Miyazaki, H Nakata
Chest 124 (6), 2136-2142, 2003
842003
Chemical exchange saturation transfer MR imaging: preliminary results for differentiation of malignant and benign thoracic lesions
Y Ohno, M Yui, H Koyama, T Yoshikawa, S Seki, Y Ueno, M Miyazaki, ...
Radiology 279 (2), 578-589, 2016
832016
MR imaging using ECG-prep scan
M Miyazaki, S Sugiura
US Patent 6,801,800, 2004
772004
MR imaging providing tissue/blood contrast image
M Miyazaki
US Patent 7,254,437, 2007
73*2007
Defective activity of recombinant cytochromes P450 3A4. 2 and 3A4. 16 in oxidation of midazolam, nifedipine, and testosterone
M Miyazaki, K Nakamura, Y Fujita, FP Guengerich, R Horiuchi, ...
Drug Metabolism and Disposition 36 (11), 2287-2291, 2008
712008
The system can't perform the operation now. Try again later.
Articles 1–20