Damian Siedlecki
Damian Siedlecki
Department of Optics and Photonics, Wroclaw University of Science and Technology
在 pwr.edu.pl 的電子郵件地址已通過驗證 - 首頁
標題
引用次數
引用次數
年份
Optical distortion correction in optical coherence tomography for quantitative ocular anterior segment by three-dimensional imaging
S Ortiz, D Siedlecki, I Grulkowski, L Remon, D Pascual, M Wojtkowski, ...
Optics express 18 (3), 2782-2796, 2010
1542010
Optical coherence tomography for quantitative surface topography
S Ortiz, D Siedlecki, L Remon, S Marcos
Applied optics 48 (35), 6708-6715, 2009
812009
Three-dimensional reconstruction of the crystalline lens gradient index distribution from OCT imaging
A de Castro, S Ortiz, E Gambra, D Siedlecki, S Marcos
Optics express 18 (21), 21905-21917, 2010
802010
Corneal topography from spectral optical coherence tomography (sOCT)
S Ortiz, D Siedlecki, P Pérez-Merino, N Chia, A de Castro, M Szkulmowski, ...
Biomedical optics express 2 (12), 3232-3247, 2011
712011
Schematic eye with a gradient-index lens and aspheric surfaces
D Siedlecki, H Kasprzak, BK Pierscionek
Optics letters 29 (11), 1197-1199, 2004
582004
Radial gradient index intraocular lens: a theoretical model
D Siedlecki, H Kasprzak, BK Pierscionek
Journal of Modern Optics 55 (4-5), 639-647, 2008
482008
Distortions of the posterior surface in optical coherence tomography images of the isolated crystalline lens: effect of the lens index gradient
D Borja, D Siedlecki, A de Castro, S Uhlhorn, S Ortiz, E Arrieta, JM Parel, ...
Biomedical Optics Express 1 (5), 1331-1340, 2010
432010
Age-dependent variation of the gradient index profile in human crystalline lenses
A De Castro, D Siedlecki, D Borja, S Uhlhorn, JM Parel, F Manns, ...
Journal of modern optics 58 (19-20), 1781-1787, 2011
422011
Distortion correction of OCT images of the crystalline lens: GRIN approach
D Siedlecki, A De Castro, E Gambra, S Ortiz, D Borja, S Uhlhorn, F Manns, ...
Optometry and Vision Science 89 (5), E709, 2012
302012
On the longitudinal chromatic aberration of the intraocular lenses
D Siedlecki, HS Ginis
Optometry and vision science 84 (10), 984-989, 2007
302007
Three-dimensional ray tracing on Delaunay-based reconstructed surfaces
S Ortiz, D Siedlecki, L Remon, S Marcos
Applied optics 48 (20), 3886-3893, 2009
292009
Retinal images in a model of a pseudophakic eye with classic and hybrid intraocular lenses
D Siedlecki, M Zając, J Nowak
Journal of Modern Optics 55 (4-5), 653-669, 2008
172008
In vivo longitudinal chromatic aberration of pseudophakic eyes
D Siedlecki, A Józwik, M Zajac, A Hill-Bator, A Turno-Krecicka
Optometry and Vision Science 91 (2), 240-246, 2014
142014
Placement of a crystalline lens and intraocular lens: retinal image quality
D Siedlecki, J Nowak, M Zajac
Journal of biomedical optics 11 (5), 054012, 2006
132006
Analysis of Purkinje images as an effective method for estimation of intraocular lens implant location in the eyeball
A Jóźwik, D Siedlecki, M Zając
Optik 125 (20), 6021-6025, 2014
82014
Optical performance of the eye with progressive addition lens correction
A Barcik, D Siedlecki
Optik 121 (21), 1937-1940, 2010
72010
Physical model of human eye with implantable intraocular lenses
A Barcik, J Nowak, D Siedlecki, M Zając, J Zarówny
16th Polish-Slovak-Czech Optical Conference on Wave and Quantum Aspects of …, 2008
62008
Dynamic changes in corneal topography and its influence on the point-spread function of the eye
D Siedlecki, H Kasprzak, BK Pierscionek
Applied optics 46 (8), 1361-1366, 2007
62007
Influence of material and haptic design on the mechanical stability of intraocular lenses by means of finite-element modeling
LR Martin, D Siedlecki, I Cabeza-Gil, B Calvo
Journal of biomedical optics 23 (3), 035003, 2018
52018
Verification of numerical algorithm for crystalline lens location in the eyeball basing on Purkinje images
A Jóźwik, D Siedlecki, M Zając
Optik 124 (13), 1581-1584, 2013
42013
系統目前無法執行作業,請稍後再試。
文章 1–20