Follow
Nicolas Foin
Nicolas Foin
National Heart Centre Singapore, Duke-NUS Graduate Medical School Singapore
Verified email at nhcs.com.sg
Title
Cited by
Cited by
Year
Diagnostic classification of the instantaneous wave-free ratio is equivalent to fractional flow reserve and is not improved with adenosine administration: results of CLARIFY …
S Sen, KN Asrress, S Nijjer, R Petraco, IS Malik, RA Foale, GW Mikhail, ...
Journal of the American College of Cardiology 61 (13), 1409-1420, 2013
3032013
Incomplete stent apposition causes high shear flow disturbances and delay in neointimal coverage as a function of strut to wall detachment distance: implications for the …
N Foin, JL Gutiérrez-Chico, S Nakatani, R Torii, CV Bourantas, S Sen, ...
Circulation: Cardiovascular Interventions 7 (2), 180-189, 2014
2282014
Classification performance of instantaneous wave-free ratio (iFR) and fractional flow reserve in a clinical population of intermediate coronary stenoses: results of the ADVISE …
R Petraco, J Escaned, S Sen, S Nijjer, KN Asrress, M Echavarria-Pinto, ...
EuroIntervention 9 (1), 91-101, 2013
2042013
Baseline instantaneous wave-free ratio as a pressure-only estimation of underlying coronary flow reserve: results of the JUSTIFY-CFR Study (Joined Coronary Pressure and Flow …
R Petraco, TP Van De Hoef, S Nijjer, S Sen, MA Van Lavieren, RA Foale, ...
Circulation: Cardiovascular Interventions 7 (4), 492-502, 2014
1932014
Impact of stent strut design in metallic stents and biodegradable scaffolds
N Foin, RD Lee, R Torii, JL Guitierrez-Chico, A Mattesini, S Nijjer, S Sen, ...
International journal of cardiology 177 (3), 800-808, 2014
1842014
Pre-angioplasty instantaneous wave-free ratio pullback provides virtual intervention and predicts hemodynamic outcome for serial lesions and diffuse coronary artery disease
SS Nijjer, S Sen, R Petraco, J Escaned, M Echavarria-Pinto, C Broyd, ...
JACC: Cardiovascular Interventions 7 (12), 1386-1396, 2014
1562014
ABSORB biodegradable stents versus second-generation metal stents: a comparison study of 100 complex lesions treated under OCT guidance
A Mattesini, GG Secco, G Dall'Ara, M Ghione, JC Rama-Merchan, A Lupi, ...
JACC: Cardiovascular interventions 7 (7), 741-750, 2014
1522014
Bioresorbable stents: Current and upcoming bioresorbable technologies
HY Ang, H Bulluck, P Wong, SS Venkatraman, Y Huang, N Foin
International journal of cardiology 228, 931-939, 2017
1512017
Biomechanical stress in coronary atherosclerosis: emerging insights from computational modelling
V Thondapu, CV Bourantas, N Foin, IK Jang, PW Serruys, P Barlis
European heart journal 38 (2), 81-92, 2017
1442017
Kissing balloon or sequential dilation of the side branch and main vessel for provisional stenting of bifurcations: lessons from micro-computed tomography and computational …
N Foin, R Torii, P Mortier, M De Beule, N Viceconte, PH Chan, JE Davies, ...
JACC: Cardiovascular Interventions 5 (1), 47-56, 2012
1352012
Maximal expansion capacity with current DES platforms: a critical factor for stent selection in the treatment of left main bifurcations
N Foin, S Sen, E Allegria, R Petraco, S Nijjer, DP Francis, C Di Mario, ...
EuroIntervention 8 (11), 1315-1325, 2013
1172013
Optical coherence tomography: from research to practice
JL Gutierrez-Chico, E Alegría-Barrero, R Teijeiro-Mestre, PH Chan, ...
European Heart Journal–Cardiovascular Imaging 13 (5), 370-384, 2012
1162012
Optical coherence tomography for guidance of distal cell recrossing in bifurcation stenting: choosing the right cell matters
E Alegria-Barrero, N Foin, PH Chan, D Syrseloudis, AC Lindsay, ...
EuroIntervention 8 (2), 205-213, 2012
1142012
Biomechanical modeling to improve coronary artery bifurcation stenting: expert review document on techniques and clinical implementation
AP Antoniadis, P Mortier, G Kassab, G Dubini, N Foin, Y Murasato, ...
Cardiovascular Interventions 8 (10), 1281-1296, 2015
1112015
Final proximal post-dilatation is necessary after kissing balloon in bifurcation stenting
N Foin, GG Secco, L Ghilencea, R Krams, C Di Mario
EuroIntervention 7 (5), 597-604, 2011
1092011
Very high-pressure dilatation for undilatable coronary lesions: indications and results with a new dedicated balloon
GG Secco, M Ghione, A Mattesini, G Dall’Ara, L Ghilencea, K Kilickesmez, ...
EuroIntervention 12 (3), 359-365, 2016
1052016
Over-expansion capacity and stent design model: an update with contemporary DES platforms
J Ng, N Foin, HY Ang, JM Fam, S Sen, S Nijjer, R Petraco, C Di Mario, ...
International journal of cardiology 221, 171-179, 2016
982016
Local hemodynamic forces after stenting: implications on restenosis and thrombosis
J Ng, CV Bourantas, R Torii, HY Ang, E Tenekecioglu, PW Serruys, N Foin
Arteriosclerosis, thrombosis, and vascular biology 37 (12), 2231-2242, 2017
952017
Mechanical behavior of polymer-based vs. metallic-based bioresorbable stents
HY Ang, YY Huang, ST Lim, P Wong, M Joner, N Foin
Journal of thoracic disease 9 (Suppl 9), S923, 2017
932017
Inducing Persistent Flow Disturbances Accelerates Atherogenesis and Promotes Thin Cap Fibroatheroma Development in D374Y-PCSK9 Hypercholesterolemic …
RM Pedrigi, CB Poulsen, VV Mehta, N Ramsing Holm, N Pareek, AL Post, ...
Circulation 132 (11), 1003-1012, 2015
812015
The system can't perform the operation now. Try again later.