Follow
Cenk Cy Yavuzturk
Title
Cited by
Cited by
Year
A short time step response factor model for vertical ground loop heat exchangers
C Yavuzturk, JD Spitler
ASHRAE transactions 105 (2), 475-485, 1999
5531999
A transient two-dimensional finite volume model for the simulation of vertical U-tube ground heat exchangers
C Yavuzturk, JD Spitler, SJ Rees
ASHRAE transactions 105 (2), 465-474, 1999
3911999
Modeling of vertical ground loop heat exchangers for ground source heat pump systems
C Yavuzturk
Oklahoma State University, 1999
2651999
Comparative study of operating and control strategies for hybrid ground-source heat pump systems using a short time step simulation model
C Yavuzturk, JD Spitler
Ashrae Transactions 106, 192, 2000
2642000
Assessment of temperature fluctuations in asphalt pavements due to thermal environmental conditions using a two-dimensional, transient finite-difference approach
C Yavuzturk, K Ksaibati, AD Chiasson
Journal of Materials in Civil Engineering 17 (4), 465-475, 2005
2242005
Assessment of the viability of hybrid geothermal heat pump systems with solar thermal collectors
AD Chiasson, C Yavuzturk
ASHRAE transactions 109, 487, 2003
1492003
Analysis of heat and mass transfer phenomena in hollow fiber membranes used for evaporative cooling
DW Johnson, C Yavuzturk, J Pruis
Journal of Membrane Science 227 (1-2), 159-171, 2003
1012003
Performance analysis of U-tube, concentric tube, and standing column well ground heat exchangers using a system simulation approach
C Yavuzturk, AD Chiasson
ASHRAE transactions 108, 925, 2002
962002
Field validation of a short time step model for vertical ground-loop heat exchangers/Discussion
C Yavuzturk, JD Spitler
ASHRAE Transactions 107, 617, 2001
892001
In situ measurement of ground thermal properties
JD Spitler, C Yavuzturk, SJ Rees
Proceedings of the Terrastock; Stuttgart, 165-70, 2000
562000
More comments on in-situ borehole thermal conductivity testing
JD Spitler, S Rees, C Yavuzturk
The Source 12 (2), 4-6, 1999
471999
Linearized approach for predicting thermal stresses in asphalt pavements due to environmental conditions
AD Chiasson, C Yavuzturk, K Ksaibati
Journal of materials in civil engineering 20 (2), 118-127, 2008
452008
Design of school building HVAC retrofit with hybrid geothermal heat-pump system
AD Chiasson, C Yavuzturk, WJ Talbert
Journal of architectural engineering 10 (3), 103-111, 2004
312004
A Design Tool for Hybrid Geothermal Heat Pump Systems in Cooling-Dominated Buildings.
AD Chiasson, C Yavuzturk
ASHRAE Transactions 115 (2), 2009
302009
Simulation Model for Ground Loop Heat Exchangers.
C Yavuzturk, AD Chiasson, JE Nydahl
Ashrae Transactions 115 (2), 2009
242009
On the effect of graphene nanoplatelets on water–graphene nanofluid thermal conductivity, viscosity, and heat transfer under laminar external flow conditions
B Bahaya, DW Johnson, CC Yavuzturk
Journal of Heat Transfer 140 (6), 064501, 2018
222018
Optimization of the Ground Thermal Response in Hybrid Geothermal Heat Pump Systems.
AD Chiasson, CC Yavuzturk, DW Johnson, TP Filburn
ASHRAE Transactions 116 (1), 2010
222010
Simulation and optimization of ground source heat pump systems
JD Spitler, X Liu, SJ Rees, C Yavuzturk
8th international energy agency heat pump conference. Las Vegas. May, 2005
172005
Formaldehyde removal from air during membrane air humidification evaporative cooling: Effects of contactor design and operating conditions
DW Johnson, CC Yavuzturk, AS Rangappa
Journal of Membrane Science 354 (1-2), 55-62, 2010
162010
Evaluation of electricity generation from underground coal fires and waste banks
AD Chiasson, C Yavuzturk, DE Walrath
142007
The system can't perform the operation now. Try again later.
Articles 1–20