Follow
Waldemar Zylka
Waldemar Zylka
Professor Medical Engineering, Westphalian University, Campus Gelsenkirchen
Verified email at w-hs.de - Homepage
Title
Cited by
Cited by
Year
A comparison between simulations and various approximations for Hookean dumbbells with hydrodynamic interaction
W Zylka, HC Öttinger
The Journal of chemical physics 90 (1), 474-480, 1989
951989
Method for the detection and correction of image distortions in medical imaging
HA Wischmann, W Zylka
US Patent 5,872,829, 1999
831999
Method of determining the position of a medical instrument
W Zylka, J Sabczynski, J Weese
US Patent 6,542,770, 2003
692003
Imaging modality for image guided surgery
W Zylka, R Proksa, WP Van Der Brug
US Patent 6,490,477, 2002
682002
Gaussian approximation and Brownian dynamics simulations for Rouse chains with hydrodynamic interaction undergoing simple shear flow
W Zylka
The Journal of chemical physics 94 (6), 4628-4636, 1991
661991
The easi project-improving the effectiveness and quality of image-guided surgery
M Breeuwer, JP Wadley, HLT De Bliek, J Buurman, PAC Desmedt, ...
IEEE Transactions on Information Technology in Biomedicine 2 (3), 156-168, 1998
591998
Detection and correction of geometric distortion in 3D MR images
MM Breeuwer, M Holden, W Zylka
International Society for Optics and Photonics, Medical Imaging 2001: Image …, 2001
582001
Detection and correction of geometric distortion in 3D CT/MR images
M Breeuwer, W Zylka, J Wadley, A Falk
International Congress Series, Computer Assisted Radiology and Surgery 1999, 1999
581999
Method of localizing objects in interventional radiology
V Rasche, G Schmitz, J Sabczynski, W Zylka, JJ Van Vaals
US Patent 6,574,493, 2003
552003
Calculation of various universal properties for dilute polymer solutions undergoing shear flow
W Zylka, HC Ottinger
Macromolecules 24 (2), 484-494, 1991
431991
X-ray examination apparatus and method for generating distortion-free X-ray images
W Zylka, J Sabczynski, J Weese
US Patent 6,379,043, 2002
332002
Experimental evaluation of an MRI compatible telerobotic system for CT MRI guided interventions
A Melzer, B Gutmann, A Lukoschek, M Mark, W Zylka, H Fischer
Supplement to Radiology 226, 409-444, 2003
252003
A Gaussian approach for the calculation of the accuracy of stereotactic frame systems
W Zylka, J Sabczynski, G Schmitz
Medical Physics 26 (3), 381-391, 1999
251999
A numerical investigation of RF heating effects on implants during MRI compared to experimental measurements
J Stenschke, D Li, M Thomann, G Schaefers, W Zylka
Advances in Medical Engineering, 53-58, 2007
242007
On geometric distortions in CT images
W Zylka, HA Wischmann
Proceedings of 18th Annual International Conference of the IEEE Engineering …, 1996
241996
Accuracy analysis for image-guided neurosurgery using fiducial skin markers, 3D CT imaging, and an optical localizer system
M Fuchs, H Wischmann, A Neumann, J Weese, W Zylka, J Sabczynski, ...
Computer assisted radiology 1124, 770-775, 1996
231996
X-ray examination device and method for producing undistorted x-ray images
W Zylka, J Sabczynski, J Weese
US Patent 6,471,399, 2002
222002
On the relaxation spectra for models of dilute polymer solutions
HC Öttinger, W Zylka
Journal of Rheology 36 (5), 885-910, 1992
171992
Effect of localization devices and registration methods on the accuracy of stereotactic frame systems predicted by the Gaussian approach
W Zylka, J Sabczynski
Computer Aided Surgery: Official Journal of the International Society for …, 1999
121999
Image‐guided reconstruction of the anterior cruciate ligament
J Sabczynski, SPM Dries, W Zylka, E Hille
The International Journal of Medical Robotics and Computer Assisted Surgery …, 2004
112004
The system can't perform the operation now. Try again later.
Articles 1–20