Ludvic Zrinzo
Ludvic Zrinzo
UCL Institute of Neurology
Verified email at ucl.ac.uk
TitleCited byYear
Adaptive deep brain stimulation in advanced Parkinson disease
S Little, A Pogosyan, S Neal, B Zavala, L Zrinzo, M Hariz, T Foltynie, ...
Annals of neurology 74 (3), 449-457, 2013
5292013
Resting oscillatory cortico-subthalamic connectivity in patients with Parkinson’s disease
V Litvak, A Jha, A Eusebio, R Oostenveld, T Foltynie, P Limousin, L Zrinzo, ...
Brain 134 (2), 359-374, 2010
2552010
Reducing hemorrhagic complications in functional neurosurgery: a large case series and systematic literature review
L Zrinzo, T Foltynie, P Limousin, MI Hariz
Journal of neurosurgery 116 (1), 84-94, 2012
2352012
Deep brain stimulation can suppress pathological synchronisation in parkinsonian patients
A Eusebio, W Thevathasan, LD Gaynor, A Pogosyan, E Bye, T Foltynie, ...
Journal of Neurology, Neurosurgery & Psychiatry 82 (5), 569-573, 2011
2332011
Confirmation of functional zones within the human subthalamic nucleus: patterns of connectivity and sub-parcellation using diffusion weighted imaging
C Lambert, L Zrinzo, Z Nagy, A Lutti, M Hariz, T Foltynie, B Draganski, ...
Neuroimage 60 (1), 83-94, 2012
2142012
MRI-guided STN DBS in Parkinson's disease without microelectrode recording: efficacy and safety
T Foltynie, L Zrinzo, I Martinez-Torres, E Tripoliti, E Petersen, E Holl, ...
Journal of Neurology, Neurosurgery & Psychiatry 82 (4), 358-363, 2011
1902011
Deep brain stimulation between 1947 and 1987: the untold story
MI Hariz, P Blomstedt, L Zrinzo
Neurosurgical focus 29 (2), E1, 2010
1692010
Effect of electrode contact location on clinical efficacy of pallidal deep brain stimulation in primary generalised dystonia
S Tisch, L Zrinzo, P Limousin, KP Bhatia, N Quinn, K Ashkan, M Hariz
Journal of Neurology, Neurosurgery & Psychiatry 78 (12), 1314-1319, 2007
1542007
Intra-operative recordings of local field potentials can help localize the subthalamic nucleus in Parkinson's disease surgery
CC Chen, A Pogosyan, LU Zrinzo, S Tisch, P Limousin, K Ashkan, ...
Experimental neurology 198 (1), 214-221, 2006
1522006
Stereotactic localization of the human pedunculopontine nucleus: atlas-based coordinates and validation of a magnetic resonance imaging protocol for direct localization
L Zrinzo, LV Zrinzo, S Tisch, PD Limousin, TA Yousry, F Afshar, MI Hariz
Brain 131 (6), 1588-1598, 2008
1412008
Effects of subthalamic stimulation on speech of consecutive patients with Parkinson disease
E Tripoliti, L Zrinzo, I Martinez-Torres, E Frost, S Pinto, T Foltynie, E Holl, ...
Neurology 76 (1), 80-86, 2011
1392011
Resting state functional MRI in Parkinson’s disease: the impact of deep brain stimulation on ‘effective’connectivity
J Kahan, M Urner, R Moran, G Flandin, A Marreiros, L Mancini, M White, ...
Brain 137 (4), 1130-1144, 2014
1332014
Effects of contact location and voltage amplitude on speech and movement in bilateral subthalamic nucleus deep brain stimulation
E Tripoliti, L Zrinzo, I Martinez‐Torres, S Tisch, E Frost, E Borrell, MI Hariz, ...
Movement disorders: official journal of the Movement Disorder Society 23 (16 …, 2008
1212008
Movement-related changes in local and long-range synchronization in Parkinson's disease revealed by simultaneous magnetoencephalography and intracranial recordings
V Litvak, A Eusebio, A Jha, R Oostenveld, G Barnes, T Foltynie, ...
Journal of Neuroscience 32 (31), 10541-10553, 2012
1142012
Alpha oscillations in the pedunculopontine nucleus correlate with gait performance in parkinsonism
W Thevathasan, A Pogosyan, JA Hyam, N Jenkinson, T Foltynie, ...
Brain 135 (1), 148-160, 2012
1082012
Future of brain stimulation: new targets, new indications, new technology
M Hariz, P Blomstedt, L Zrinzo
Movement Disorders 28 (13), 1784-1792, 2013
1072013
Bilateral adaptive deep brain stimulation is effective in Parkinson's disease
S Little, M Beudel, L Zrinzo, T Foltynie, P Limousin, M Hariz, S Neal, ...
J Neurol Neurosurg Psychiatry 87 (7), 717-721, 2016
1032016
Variability of the subthalamic nucleus: the case for direct MRI guided targeting
K Ashkan, P Blomstedt, L Zrinzo, S Tisch, T Yousry, P Limousin-Dowsey, ...
British journal of neurosurgery 21 (2), 197-200, 2007
982007
The risk of hardware infection in deep brain stimulation surgery is greater at impulse generator replacement than at the primary procedure
J Pepper, L Zrinzo, B Mirza, T Foltynie, P Limousin, M Hariz
Stereotactic and functional neurosurgery 91 (1), 56-65, 2013
932013
Long-term outcome of subthalamic nucleus deep brain stimulation for Parkinson's disease using an MRI-guided and MRI-verified approach
I Aviles-Olmos, Z Kefalopoulou, E Tripoliti, J Candelario, H Akram, ...
J Neurol Neurosurg Psychiatry 85 (12), 1419-1425, 2014
912014
The system can't perform the operation now. Try again later.
Articles 1–20