Validation of an optical system to measure acetabular shell deformation in cadavers P Dold, MC Bone, M Flohr, R Preuss, TJ Joyce, D Deehan, J Holland Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2014 | 38 | 2014 |
Validation of an optical system to measure acetabular shell deformation in cadavers P Dold, MC Bone, M Flohr, R Preuss, TJ Joyce, D Deehan, J Holland Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2014 | 38 | 2014 |
Investigation of taper failure in a contemporary metal-on-metal hip arthroplasty system through examination of unused and explanted prostheses D Langton, I Ahmed, P Avery, M Bone, N Cooke, D Deehan, P Duffy, ... JBJS 99 (5), 427-436, 2017 | 27 | 2017 |
Determining material loss from the femoral stem trunnion in hip arthroplasty using a coordinate measuring machine MC Bone, RP Sidaginamale, JK Lord, SC Scholes, TJ Joyce, AVF Nargol, ... Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2015 | 26 | 2015 |
Surface finish of the Exeter Trauma Stem: a cause for concern? TG Petheram, M Bone, TJ Joyce, I Serrano-Pedraza, MR Reed, ... The Bone & Joint Journal 95 (2), 173-176, 2013 | 14 | 2013 |
Surface finish of the Exeter Trauma Stem: a cause for concern? TG Petheram, M Bone, TJ Joyce, I Serrano-Pedraza, MR Reed, ... The Bone & Joint Journal 95 (2), 173-176, 2013 | 14 | 2013 |
In vitro wear testing of the PyroCarbon proximal interphalangeal joint replacement: Five million cycles of flexion and extension A Naylor, MC Bone, A Unsworth, SC Talwalkar, IA Trail, TJ Joyce Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2015 | 13 | 2015 |
The influence of the strength of bone on the deformation of acetabular shells: a laboratory experiment in cadavers MC Bone, P Dold, M Flohr, R Preuss, TJ Joyce, RM Aspden, J Holland, ... The Bone & Joint Journal 97 (4), 473-477, 2015 | 12 | 2015 |
The influence of the strength of bone on the deformation of acetabular shells: a laboratory experiment in cadavers MC Bone, P Dold, M Flohr, R Preuss, TJ Joyce, RM Aspden, J Holland, ... The Bone & Joint Journal 97 (4), 473-477, 2015 | 12 | 2015 |
Acetabular shell deformation as a function of shell stiffness and bone strength P Dold, T Pandorf, M Flohr, R Preuss, MC Bone, TJ Joyce, J Holland, ... Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2016 | 11 | 2016 |
An analysis of explanted pyrolytic carbon prostheses MC Bone, G Giddins, TJ Joyce Journal of Hand Surgery (European Volume) 39 (6), 666-667, 2014 | 11 | 2014 |
A novel method for measuring acetabular cup deformation in cadavers MC Bone, P Dold, M Flohr, R Preuss, TJ Joyce, D Deehan, J Holland Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2013 | 11 | 2013 |
Analysis of failed Van Straten LPM proximal interphalangeal prostheses MC Bone, JL Cunningham, J Lord, G Giddins, J Field, TJ Joyce Journal of Hand Surgery (European Volume) 38 (3), 313-320, 2013 | 8 | 2013 |
Failure of an ACCIS metal-on-metal hip resurfacing prosthesis: A case report MC Bone, A Naylor Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2017 | 2 | 2017 |
Evaluating the wear and surface roughness of pyrocarbon finger prostheses tested in vitro A Naylor, MC Bone, A Unsworth, SC Talwalkar, IA Trail, TJ Joyce Proceedings of the 10th Anniversary Bath Biomechanics Symposium: Current …, 2014 | 2 | 2014 |
A comparison of ex vivo, in vitro tested, and unused pyrolytic carbon prostheses A Naylor, MC Bone, G Giddins, SC Talwalkar, IA Trail, TJ Joyce Proceedings of the Combined Meeting of the Australian Hand Surgery Society …, 2016 | 1 | 2016 |
CLINICAL AND WEAR HISTORIES ANALYSED FOR 30-YEAR MOM AND 32-YEAR COC RETRIEVALS TO ESTABLISH LONG-TERM WEAR-RATES. I Clarke, M Burgett-Moreno, M Bone, S Scholes, T Joyce, T Donaldson Orthopaedic Proceedings 98 (SUPP_7), 87-87, 2016 | | 2016 |
ACETABULAR SHELL DEFORMATION AS A FUNCTION OF STIFFNESS AND BONE STRENGTH P Dold, T Pandorf, M Flohr, R Preuss, M Bone, J Holland, D Deehan Orthopaedic Proceedings 98 (SUPP_7), 115-115, 2016 | | 2016 |
Topographical evaluation of pyrolytic carbon finger prostheses A Naylor, M Bone, S Talwalkar, IA Trail, G Giddins, TJ Joyce Engineering the Upper Limb, 2016 | | 2016 |
Analysis of a Surface Engineered Metal on Metal Hip Resurfacing: A Case Study MC Bone, A Naylor, DJ Langton, TJ Joyce Hip Surgery: A Joint Engineering and Surgical Challenge, 2015 | | 2015 |