Comparison of friction and lubrication of different hip prostheses SC Scholes, A Unsworth Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2000 | 205 | 2000 |
A frictional study of total hip joint replacements SC Scholes, A Unsworth, AAJ Goldsmith Physics in Medicine & Biology 45 (12), 3721, 2000 | 148 | 2000 |
Wear studies on the likely performance of CFR-PEEK/CoCrMo for use as artificial joint bearing materials SC Scholes, A Unsworth Journal of Materials Science: Materials in Medicine 20 (1), 163-170, 2009 | 145 | 2009 |
The effects of material combination and lubricant on the friction of total hip prostheses SC Scholes, A Unsworth, RM Hall, R Scott Wear 241 (2), 209-213, 2000 | 145 | 2000 |
The effects of proteins on the friction and lubrication of artificial joints SC Scholes, A Unsworth Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2006 | 123 | 2006 |
The wear of metal-on-metal total hip prostheses measured in a hip simulator SC Scholes, SM Green, A Unsworth Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2001 | 103 | 2001 |
The effect of ‘running-in’on the tribology and surface morphology of metal-on-metal Birmingham hip resurfacing device in simulator studies K Vassiliou, AP D Elfick, SC Scholes, A Unsworth Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2006 | 87 | 2006 |
The wear properties of CFR-PEEK-OPTIMA articulating against ceramic assessed on a multidirectional pin-on-plate machine SC Scholes, A Unsworth Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2007 | 78 | 2007 |
Tribological assessment of a flexible carbon-fibre-reinforced poly (ether—ether—ketone) acetabular cup articulating against an alumina femoral head SC Scholes, IA Inman, A Unsworth, E Jones Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2008 | 72 | 2008 |
Pitch-based carbon-fibre-reinforced poly (ether—ether—ketone) OPTIMA® assessed as a bearing material in a mobile bearing unicondylar knee joint SC Scholes, A Unsworth Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2009 | 64 | 2009 |
Compliant layer acetabular cups: friction testing of a range of materials and designs for a new generation of prosthesis that mimics the natural joint SC Scholes, IC Burgess, HR Marsden, A Unsworth, E Jones, N Smith Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2006 | 60 | 2006 |
A multi‐directional wear screening device and preliminary results of UHMWPE articulating against stainless steel TJ Joyce, D Monk, SC Scholes, A Unsworth Bio-medical materials and engineering 10 (3-4), 241-249, 2000 | 60 | 2000 |
Pin-on-plate studies on the effect of rotation on the wear of metal-on-metal samples SC Scholes, A Unsworth Journal of materials science: Materials in medicine 12 (4), 299-303, 2001 | 54 | 2001 |
The wear performance of PEEK-OPTIMA based self-mating couples SC Scholes, A Unsworth Wear 268 (3-4), 380-387, 2010 | 49 | 2010 |
The tribology of metal-on-metal total hip replacements SC Scholes, A Unsworth Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2006 | 49 | 2006 |
Polyurethane unicondylar knee prostheses: simulator wear tests and lubrication studies SC Scholes, A Unsworth, E Jones Physics in Medicine & Biology 52 (1), 197, 2006 | 48 | 2006 |
Topographical analysis of the femoral components of ex vivo total knee replacements SC Scholes, E Kennard, R Gangadharan, D Weir, J Holland, D Deehan, ... Journal of Materials Science: Materials in Medicine 24, 547-554, 2013 | 42 | 2013 |
Design aspects of compliant, soft layer bearings for an experimental hip prosthesis SC Scholes, A Unsworth, JM Blamey, IC Burges, E Jones, N Smith Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2005 | 40 | 2005 |
In vitro wear testing of a contemporary design of reverse shoulder prosthesis SL Smith, BL Li, A Buniya, SH Lin, SC Scholes, G Johnson, TJ Joyce Journal of biomechanics 48 (12), 3072-3079, 2015 | 30 | 2015 |
Investigation of taper failure in a contemporary metal-on-metal hip arthroplasty system through examination of unused and explanted prostheses D Langton, I Ahmed, P Avery, M Bone, N Cooke, D Deehan, P Duffy, ... JBJS 99 (5), 427-436, 2017 | 27 | 2017 |