Follow
Duane A. Morrow
Duane A. Morrow
Assistant Professor of Biomedical Engineering, Mayo Clinic
Verified email at mayo.edu
Title
Cited by
Cited by
Year
Transversely isotropic tensile material properties of skeletal muscle tissue
DA Morrow, TLH Donahue, GM Odegard, KR Kaufman
Journal of the mechanical behavior of biomedical materials 3 (1), 124-129, 2010
2422010
Determination of thein situ forces and force distribution within the human anterior cruciate ligament
GA Livesay, H Fujie, S Kashiwaguchi, DA Morrow, FH Fu, SLY Woo
Annals of Biomedical Engineering 23, 467-474, 1995
1701995
Constitutive modeling of skeletal muscle tissue with an explicit strain-energy function
GM Odegard, TL Haut Donahue, DA Morrow, KR Kaufman
732008
Surgical therapy for tremor in multiple sclerosis: an evaluation of outcome measures
J Matsumoto, D Morrow, K Kaufman, D Davis, JE Ahlskog, A Walker, ...
Neurology 57 (10), 1876-1882, 2001
732001
Electromyographic activity in the immobilized shoulder girdle musculature during contralateral upper limb movements
J Smith, DJ Padgett, DL Dahm, KR Kaufman, SP Harrington, DA Morrow, ...
Journal of shoulder and elbow surgery 13 (6), 583-588, 2004
692004
The effect of visual biofeedback on the propulsion effectiveness of experienced wheelchair users
BR Kotajarvi, JR Basford, KN An, DA Morrow, KR Kaufman
Archives of Physical Medicine and Rehabilitation 87 (4), 510-515, 2006
672006
Performance characteristics of a pressure microsensor
KR Kaufman, T Wavering, D Morrow, J Davis, RL Lieber
Journal of biomechanics 36 (2), 283-287, 2003
532003
Skeletal muscle tensile strain dependence: Hyperviscoelastic nonlinearity
BB Wheatley, DA Morrow, GM Odegard, KR Kaufman, TLH Donahue
Journal of the mechanical behavior of biomedical materials 53, 445-454, 2016
482016
Reference values for shear wave elastography of neck and shoulder muscles in healthy individuals
C Ewertsen, J Carlsen, MA Perveez, H Schytz
Ultrasound international open 4 (01), E23-E29, 2018
372018
Clinical experience of a new NPWT system in diabetic foot ulcers and post-amputation wounds
G Stansby, V Wealleans, L Wilson, D Morrow, C Gooday, K Dhatariya
Journal of wound care 19 (11), 496-502, 2010
342010
Intraneural ganglia: a clinical problem deserving a mechanistic explanation and model
BE SHREEHARI ELANGOVAN, GM Odegard, DA Morrow, RJ SPINNER
Neurosurg. Focus 26 (2), 1, 2009
292009
A method for assessing the fit of a constitutive material model to experimental stress–strain data
DA Morrow, T Haut Donahue, GM Odegard, KR Kaufman
Computer methods in biomechanics and biomedical engineering 13 (2), 247-256, 2010
282010
Design considerations of a fiber optic pressure sensor protective housing for intramuscular pressure measurements
SA Go, ER Jensen, SM O’Connor, LQ Evertz, DA Morrow, SR Ward, ...
Annals of biomedical engineering 45, 739-746, 2017
262017
A 2-D model of wheelchair propulsion.
DA Morrow, LY Guo, KD Zhao, FC Su, KN An
Disability and rehabilitation 25 (4-5), 192-196, 2003
252003
Performance characteristics of a new generation pressure microsensor for physiologic applications
PS Cottler, WR Karpen, DA Morrow, KR Kaufman
Annals of biomedical engineering 37, 1638-1645, 2009
222009
Characterization of three dimensional volumetric strain distribution during passive tension of the human tibialis anterior using Cine Phase Contrast MRI
ER Jensen, DA Morrow, JP Felmlee, NS Murthy, KR Kaufman
Journal of biomechanics 49 (14), 3430-3436, 2016
202016
Analysis of fluid movement in skeletal muscle using fluorescent microspheres
LQ Evertz, SM Greising, DA Morrow, GC Sieck, KR Kaufman
Muscle & nerve 54 (3), 444-450, 2016
152016
Error analysis of cine phase contrast MRI velocity measurements used for strain calculation
ER Jensen, DA Morrow, JP Felmlee, GM Odegard, KR Kaufman
Journal of biomechanics 48 (1), 95-103, 2015
142015
Evaluating the dynamic performance of a fibre optic pressure microsensor
S Chen, C Pislaru, RR Kinnick, DA Morrow, KR Kaufman, JF Greenleaf
Physiological Measurement 26 (4), N13, 2005
112005
An ultraminiature MEMS pressure sensor with high sensitivity for measurement of intramuscular pressure (IMP) in patients with neuromuscular diseases
AS Sezen, R Rajamani, D Morrow, KR Kaufman, BK Gilbert
102009
The system can't perform the operation now. Try again later.
Articles 1–20