Follow
Edmond Richer
Edmond Richer
Mechanical Engineering Department, Southern Methodist University
Verified email at lyle.smu.edu
Title
Cited by
Cited by
Year
A high performance pneumatic force actuator system: Part I—Nonlinear mathematical model
E Richer, Y Hurmuzlu
J. dyn. sys., meas., control 122 (3), 416-425, 2000
7022000
A high performance pneumatic force actuator system: part II—nonlinear controller design
E Richer, Y Hurmuzlu
J. Dyn. Sys., Meas., Control 122 (3), 426-434, 2000
2532000
Additive manufacturing of active devices using dielectric, conductive and magnetic materials
A Cohen, PS Krueger, M Saari, E Richer, B Cox, B Xia, CG Clay
US Patent 10,254,499, 2019
2142019
Validating bioluminescence imaging as a high-throughput, quantitative modality for assessing tumor burden
Z Paroo, RA Bollinger, DA Braasch, E Richer, DR Corey, PP Antich, ...
Molecular Imaging 3 (2), 15353500200403172, 2004
1902004
The role of Cdk5 in neuroendocrine thyroid cancer
K Pozo, E Castro-Rivera, C Tan, F Plattner, G Schwach, V Siegl, D Meyer, ...
Cancer cell 24 (4), 499-511, 2013
1862013
Design and characterization of a small-scale magnetorheological damper for tremor suppression
D Case, B Taheri, E Richer
Mechatronics, IEEE/ASME Transactions on 18 (1), 96-103, 2012
1102012
Fiber Encapsulation Additive Manufacturing: An Enabling Technology for 3D Printing of Electromechanical Devices and Robotic Components
M Saari, B Cox, E Richer, PS Krueger, AL Cohen
3D Printing and Additive Manufacturing 2 (1), 32-39, 2015
1042015
Force and stiffness backstepping-sliding mode controller for pneumatic cylinders
B Taheri, D Case, E Richer
IEEE/ASME Transactions on Mechatronics 19 (6), 1799-1809, 2014
1012014
Fabrication and analysis of a composite 3D printed capacitive force sensor
M Saari, B Xia, B Cox, PS Krueger, AL Cohen, E Richer
3D Printing and Additive Manufacturing 3 (3), 136-141, 2016
802016
Antivascular effects of combretastatin A4 phosphate in breast cancer xenograft assessed using dynamic bioluminescence imaging (BLI) and confirmed by magnetic resonance imaging …
D Zhao, E Richer, PP Antich, RP Mason
FASEB journal: official publication of the Federation of American Societies …, 2008
752008
Robust controller for tremor suppression at musculoskeletal level in human wrist
B Taheri, D Case, E Richer
IEEE Transactions on neural systems and rehabilitation engineering 22 (2 …, 2013
732013
The use of histone deacetylase inhibitor FK228 and DNA hypomethylation agent 5‐azacytidine in human bladder cancer therapy
JA Karam, J Fan, J Stanfield, E Richer, EA Benaim, E Frenkel, P Antich, ...
International journal of cancer 120 (8), 1795-1802, 2007
622007
Adaptive suppression of severe pathological tremor by torque estimation method
B Taheri, D Case, E Richer
IEEE/ASME Transactions on Mechatronics 20 (2), 717-727, 2014
602014
Dynamical modeling and experimental study of a small-scale magnetorheological damper
D Case, B Taheri, E Richer
IEEE/ASME Transactions on mechatronics 19 (3), 1015-1024, 2013
602013
Striatal dysregulation of Cdk5 alters locomotor responses to cocaine, motor learning, and dendritic morphology
DA Meyer, E Richer, SA Benkovic, K Hayashi, JW Kansy, CF Hale, ...
Proceedings of the National Academy of Sciences 105 (47), 18561-18566, 2008
562008
Iterative reconstruction method for light emitting sources based on the diffusion equation
NV Slavine, MA Lewis, E Richer, PP Antich
Medical physics 33 (1), 61-68, 2006
522006
Multiphysics modeling of magnetorheological dampers
D Case, B Taheri, E Richer
The International Journal of Multiphysics 7 (1), 61-76, 2013
422013
Theoretical and experimental study of efficient control of vibrations in a clamped square plate
P Shimon, E Richer, Y Hurmuzlu
Journal of Sound and vibration 282 (1-2), 453-473, 2005
382005
Reduction in normalized bone elasticity following long-term bisphosphonate treatment as measured by ultrasound critical angle reflectometry
E Richer, MA Lewis, CV Odvina, MA Vazquez, BJ Smith, RD Peterson, ...
Osteoporosis international 16, 1384-1392, 2005
352005
Bone material ultrasound velocity is predictive of whole bone strength
SS Mehta, PP Antich, MM Daphtary, DG Bronson, E Richer
Ultrasound in medicine & biology 27 (6), 861-867, 2001
332001
The system can't perform the operation now. Try again later.
Articles 1–20