Follow
Ralf Hendrik Menk
Ralf Hendrik Menk
Elettra Sincrotrone Trieste, Italy
Verified email at elettra.eu
Title
Cited by
Cited by
Year
Diffraction enhanced x-ray imaging
D Chapman, W Thomlinson, RE Johnston, D Washburn, E Pisano, ...
Physics in Medicine & Biology 42 (11), 2015, 1997
14921997
Mammography with synchrotron radiation: phase-detection techniques
F Arfelli, V Bonvicini, A Bravin, G Cantatore, E Castelli, LD Palma, ...
Radiology 215 (1), 286-293, 2000
3902000
Mammography with synchrotron radiation: first clinical experience with phase-detection technique
E Castelli, M Tonutti, F Arfelli, R Longo, E Quaia, L Rigon, D Sanabor, ...
Radiology 259 (3), 684-694, 2011
2492011
PITRE: software for phase-sensitive X-ray image processing and tomography reconstruction
RC Chen, D Dreossi, L Mancini, R Menk, L Rigon, TQ Xiao, R Longo
Journal of synchrotron radiation 19 (5), 836-845, 2012
2412012
An innovative digital imaging set‐up allowing a low‐dose approach to phase contrast applications in the medical field
A Olivo, F Arfelli, G Cantatore, R Longo, RH Menk, S Pani, M Prest, ...
Medical physics 28 (8), 1610-1619, 2001
2402001
A new DEI algorithm capable of investigating sub-pixel structures
L Rigon, HJ Besch, F Arfelli, RH Menk, G Heitner, H Plothow-Besch
Journal of Physics D: Applied Physics 36 (10A), A107, 2003
1622003
X-ray refraction effects: application to the imaging of biological tissues
RA Lewis, CJ Hall, AP Hufton, S Evans, RH Menk, F Arfelli, L Rigon, ...
The British journal of radiology 76 (905), 301-308, 2003
1562003
Functionalized Gold Nanoparticles: Detailed In Vivo Multimodal Microscopic Brain Distribution Study (vol 2, pg 2826, 2010)
F Sousa, S Mandal, C Garrovo, A Astolfo, A Bonifacio, D Latawiec, ...
NANOSCALE 3 (12), 5180-5180, 2011
137*2011
Medical applications of synchrotron radiation at the SYRMEP beamline of ELETTRA
A Abrami, F Arfelli, RC Barroso, A Bergamaschi, F Bille, P Bregant, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2005
1362005
The SYRMEP Beamline of Elettra: clinical mammography and bio‐medical applications
G Tromba, R Longo, A Abrami, F Arfelli, A Astolfo, P Bregant, F Brun, ...
AIP Conference Proceedings 1266 (1), 18-23, 2010
1202010
Measurement of the linear attenuation coefficients of breast tissues by synchrotron radiation computed tomography
RC Chen, R Longo, L Rigon, F Zanconati, A De Pellegrin, F Arfelli, ...
Physics in Medicine & Biology 55 (17), 4993, 2010
1042010
X-ray detection of structural orientation in human articular cartilage
C Muehleman, S Majumdar, AS Issever, F Arfelli, RH Menk, L Rigon, ...
Osteoarthritis and cartilage 12 (2), 97-105, 2004
1042004
Invited Article: Coherent imaging using seeded free-electron laser pulses with variable polarization: First results and research opportunities
F Capotondi, E Pedersoli, N Mahne, RH Menk, G Passos, L Raimondi, ...
Review of scientific instruments 84 (5), 2013
992013
The mammography project at the SYRMEP beamline
D Dreossi, A Abrami, F Arfelli, P Bregant, K Casarin, V Chenda, MA Cova, ...
European journal of radiology 68 (3), S58-S62, 2008
942008
Three-image diffraction enhanced imaging algorithm to extract absorption, refraction, and ultrasmall-angle scattering
L Rigon, F Arfelli, RH Menk
Applied Physics Letters 90 (11), 2007
892007
An IAEA multi-technique X-ray spectrometry endstation at Elettra Sincrotrone Trieste: benchmarking results and interdisciplinary applications
AG Karydas, M Czyzycki, JJ Leani, A Migliori, J Osan, M Bogovac, ...
Journal of Synchrotron Radiation 25 (1), 189-203, 2018
852018
Mammography imaging studies using a Laue crystal analyzer
D Chapman, W Thomlinson, F Arfelli, N Gmür, Z Zhong, R Menk, ...
Review of Scientific Instruments 67 (9), 3360-3360, 1996
801996
Gold nanoparticle labeling of cells is a sensitive method to investigate cell distribution and migration in animal models of human disease
RH Menk, E Schültke, C Hall, F Arfelli, A Astolfo, L Rigon, A Round, ...
Nanomedicine: Nanotechnology, Biology and Medicine 7 (5), 647-654, 2011
792011
Clinical mammography at the SYRMEP beam line
E Castelli, F Arfelli, D Dreossi, R Longo, T Rokvic, MA Cova, E Quaia, ...
Nuclear Instruments and Methods in Physics Research Section A: Accelerators …, 2007
762007
In vivo visualization of gold-loaded cells in mice using x-ray computed tomography
A Astolfo, E Schültke, RH Menk, RD Kirch, BHJ Juurlink, C Hall, ...
Nanomedicine: Nanotechnology, Biology and Medicine 9 (2), 284-292, 2013
662013
The system can't perform the operation now. Try again later.
Articles 1–20