Follow
Peter C Park
Title
Cited by
Cited by
Year
Comprehensive analysis of proton range uncertainties related to patient stopping-power-ratio estimation using the stoichiometric calibration
M Yang, XR Zhu, PC Park, U Titt, R Mohan, G Virshup, JE Clayton, ...
Physics in Medicine & Biology 57 (13), 4095, 2012
3892012
Effectiveness of robust optimization in intensity‐modulated proton therapy planning for head and neck cancers
W Liu, SJ Frank, X Li, Y Li, PC Park, L Dong, X Ronald Zhu, R Mohan
Medical physics 40 (5), 051711, 2013
1892013
A beam-specific planning target volume (PTV) design for proton therapy to account for setup and range uncertainties
PC Park, XR Zhu, AK Lee, N Sahoo, AD Melancon, L Zhang, L Dong
International Journal of Radiation Oncology* Biology* Physics 82 (2), e329-e336, 2012
1852012
Robust optimization in intensity-modulated proton therapy to account for anatomy changes in lung cancer patients
H Li, X Zhang, P Park, W Liu, J Chang, Z Liao, S Frank, Y Li, F Poenisch, ...
Radiotherapy and Oncology 114 (3), 367-372, 2015
1012015
Impact of respiratory motion on worst-case scenario optimized intensity modulated proton therapy for lung cancers
W Liu, Z Liao, SE Schild, Z Liu, H Li, Y Li, PC Park, X Li, J Stoker, J Shen, ...
Practical radiation oncology 5 (2), e77-e86, 2015
952015
Statistical assessment of proton treatment plans under setup and range uncertainties
PC Park, JP Cheung, XR Zhu, AK Lee, N Sahoo, SL Tucker, W Liu, H Li, ...
International Journal of Radiation Oncology* Biology* Physics 86 (5), 1007-1013, 2013
87*2013
A visually apparent and quantifiable CT imaging feature identifies biophysical subtypes of pancreatic ductal adenocarcinoma
EJ Koay, Y Lee, V Cristini, JS Lowengrub, Y Kang, FAS Lucas, BP Hobbs, ...
Clinical Cancer Research 24 (23), 5883-5894, 2018
852018
Motion‐robust intensity‐modulated proton therapy for distal esophageal cancer
J Yu, X Zhang, L Liao, H Li, R Zhu, PC Park, N Sahoo, M Gillin, Y Li, ...
Medical physics 43 (3), 1111-1118, 2016
772016
Dosimetric benefits of robust treatment planning for intensity modulated proton therapy for base-of-skull cancers
W Liu, R Mohan, P Park, Z Liu, H Li, X Li, Y Li, R Wu, N Sahoo, L Dong, ...
Practical radiation oncology 4 (6), 384-391, 2014
652014
Desktop reference for crash reduction factors
GB Bahar, M Masliah, R Wolff, P Park
United States. Federal Highway Administration. Office of Safety, 2007
472007
Proton beam therapy outcomes for localized unresectable hepatocellular carcinoma
AS Chadha, JR Gunther, CE Hsieh, M Aliru, LS Mahadevan, ...
Radiotherapy and Oncology 133, 54-61, 2019
442019
Effects of respiratory motion on passively scattered proton therapy versus intensity modulated photon therapy for stage III lung cancer: are proton plans more sensitive to …
J Matney, PC Park, J Bluett, YP Chen, W Liu, LE Court, Z Liao, H Li, ...
International Journal of Radiation Oncology* Biology* Physics 87 (3), 576-582, 2013
432013
Dose escalation with an IMRT technique in 15 to 28 fractions is better tolerated than standard doses of 3DCRT for LAPC
LE Colbert, S Moningi, A Chadha, A Amer, Y Lee, RA Wolff, ...
Advances in radiation oncology 2 (3), 403-415, 2017
352017
Perturbation of water‐equivalent thickness as a surrogate for respiratory motion in proton therapy
JE Matney, PC Park, H Li, LE Court, XR Zhu, L Dong, W Liu, R Mohan
Journal of applied clinical medical physics 17 (2), 368-378, 2016
262016
Potential use of structural layout optimization at the conceptual design stage
P Park, M Gilbert, A Tyas, O Popovic-Larsen
International Journal of Architectural Computing 10 (1), 13-32, 2012
252012
Fast range-corrected proton dose approximation method using prior dose distribution
PC Park, J Cheung, XR Zhu, N Sahoo, L Dong
Physics in Medicine & Biology 57 (11), 3555, 2012
222012
A novel dose‐based positioning method for CT image‐guided proton therapy
JP Cheung, PC Park, LE Court, X Ronald Zhu, RJ Kudchadker, SJ Frank, ...
Medical physics 40 (5), 051714, 2013
212013
MRI-based computed tomography metal artifact correction method for improving proton range calculation accuracy
PC Park, E Schreibmann, J Roper, E Elder, I Crocker, T Fox, XR Zhu, ...
International Journal of Radiation Oncology* Biology* Physics 91 (4), 849-856, 2015
172015
Patient‐specific quantification of respiratory motion‐induced dose uncertainty for step‐and‐shoot IMRT of lung cancer
H Li, P Park, W Liu, J Matney, Z Liao, P Balter, Y Li, X Zhang, X Li, XR Zhu
Medical physics 40 (12), 121712, 2013
172013
Vasculature-driven biomechanical deformable image registration of longitudinal liver cholangiocarcinoma computed tomographic scans
G Cazoulat, D Elganainy, BM Anderson, M Zaid, PC Park, EJ Koay, ...
Advances in radiation oncology 5 (2), 269-278, 2020
162020
The system can't perform the operation now. Try again later.
Articles 1–20