Follow
Hanna Burton
Hanna Burton
University of Birmingham
No verified email
Title
Cited by
Cited by
Year
The design of additively manufactured lattices to increase the functionality of medical implants
HE Burton, NM Eisenstein, BM Lawless, P Jamshidi, MA Segarra, ...
Materials Science and Engineering: C 94, 901-908, 2019
1202019
Dynamic viscoelasticity and surface properties of porcine left anterior descending coronary arteries
HE Burton, JM Freij, DM Espino
Cardiovascular engineering and technology 8, 41-56, 2017
592017
Surface finish has a critical influence on biofilm formation and mammalian cell attachment to additively manufactured prosthetics
SC Cox, P Jamshidi, NM Eisenstein, MA Webber, H Burton, RJA Moakes, ...
ACS Biomaterials Science & Engineering 3 (8), 1616-1626, 2017
532017
Reporting fidelity in the literature for computer aided design and additive manufacture of implants and guides
HE Burton, S Peel, D Eggbeer
Additive Manufacturing 23, 362-373, 2018
332018
Effect of glutaraldehyde based cross-linking on the viscoelasticity of mitral valve basal chordae tendineae
M Constable, HE Burton, BM Lawless, V Gramigna, KG Buchan, ...
Biomedical Engineering Online 17, 1-14, 2018
222018
Additively manufactured versus conventionally pressed cranioplasty implants: an accuracy comparison
S Peel, D Eggbeer, H Burton, H Hanson, PL Evans
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2018
192018
The effect of mechanical overloading on surface roughness of the coronary arteries
HE Burton, DM Espino
Applied bionics and biomechanics 2019, 2019
182019
Effects of freezing, fixation and dehydration on surface roughness properties of porcine left anterior descending coronary arteries
HE Burton, RL Williams, DM Espino
Micron 101, 78-86, 2017
172017
Towards additive manufacture of functional, spline-based morphometric models of healthy and diseased coronary arteries: in vitro proof-of-concept using a porcine template
R Jewkes, HE Burton, DM Espino
Journal of functional biomaterials 9 (1), 15, 2018
152018
Multiscale three-dimensional surface reconstruction and surface roughness of porcine left anterior descending coronary arteries
HE Burton, R Cullinan, K Jiang, DM Espino
Royal Society Open Science 6 (9), 190915, 2019
122019
Objective uniaxial identification of transition points in non-linear materials: sample application to porcine coronary arteries and the dependency of their pre-and post …
JM Freij, HE Burton, DM Espino
Cardiovascular engineering and technology, 1-8, 2018
92018
Hyperspectral chemical imaging reveals spatially varied degradation of polycarbonate urethane (PCU) biomaterials
RM Dorrepaal, BM Lawless, HE Burton, DM Espino, DET Shepherd, ...
Acta Biomaterialia 73, 81-89, 2018
82018
Mechanical testing of glutaraldehyde cross-linked mitral valves. Part one: In vitro mechanical behaviour
R Northeast, M Constable, HE Burton, BM Lawless, V Gramigna, ...
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2021
42021
Cone-beam computed tomography allows accurate registration to surgical navigation systems: a multidevice phantom study
BJ Talks, K Jolly, H Burton, H Koria, SK Ahmed
American journal of rhinology & allergy, 1945892419861849, 2019
32019
Mechanical testing of glutaraldehyde cross-linked mitral valves. Part two: Elastic and viscoelastic properties of chordae tendineae
M Constable, R Northeast, BM Lawless, HE Burton, V Gramigna, KL Goh, ...
Proceedings of the Institution of Mechanical Engineers, Part H: Journal of …, 2021
12021
Mechanical testing of glutaraldehyde cross-linked mitral valves. Part two
M Constable, R Northeast, BM Lawless, HE Burton, V Gramigna, KL Goh, ...
2020
Characterisation of coronary arteries: mechanical testing and three-dimensional imaging
HE Burton
University of Birmingham, 2018
2018
Mechanical testing of glutaraldehyde cross-linked mitral valves. Part one
R Northeast, M Constable, HE Burton, BM Lawless
The system can't perform the operation now. Try again later.
Articles 1–18