Progress in thermal comfort research over the last twenty years RJ de Dear, T Akimoto, EA Arens, G Brager, C Candido, KWD Cheong, ... Indoor air 23 (6), 442-461, 2013 | 363 | 2013 |
Field experiments on thermal comfort in campus classrooms in Taiwan RL Hwang, TP Lin, NJ Kuo Energy and Buildings 38 (1), 53-62, 2006 | 249 | 2006 |
Thermal comfort study of an air-conditioned lecture theatre in the tropics KWD Cheong, E Djunaedy, YL Chua, KW Tham, SC Sekhar, NH Wong, ... Building and environment 38 (1), 63-73, 2003 | 151 | 2003 |
A comparative study of VOCs in Singapore and European office buildings MS Zuraimi, CA Roulet, KW Tham, SC Sekhar, KWD Cheong, NH Wong, ... Building and environment 41 (3), 316-329, 2006 | 116 | 2006 |
Findings of personalized ventilation studies in a hot and humid climate SC Sekhar, N Gong, KW Tham, KW Cheong, AK Melikov, DP Wyon, ... HVAC&R Research 11 (4), 603-620, 2005 | 104 | 2005 |
Thermal comfort and IAQ assessment of under-floor air distribution system integrated with personalized ventilation in hot and humid climate R Li, SC Sekhar, AK Melikov Building and Environment 45 (9), 1906-1913, 2010 | 93 | 2010 |
The acceptable air velocity range for local air movement in the tropics N Gong, KW Tham, AK Melikov, DP Wyon, SC Sekhar, KW Cheong Hvac&r Research 12 (4), 1065-1076, 2006 | 93 | 2006 |
On the study of energy performance and life cycle cost of smart window SC Sekhar, KLC Toon Energy and Buildings 28 (3), 307-316, 1998 | 91 | 1998 |
Measurements and computations of contaminant's distribution in an office environment KWD Cheong, E Djunaedy, TK Poh, KW Tham, SC Sekhar, NH Wong, ... Building and Environment 38 (1), 135-145, 2003 | 87 | 2003 |
Higher space temperatures and better thermal comfort—a tropical analysis SC Sekhar Energy and Buildings 23 (1), 63-70, 1995 | 80 | 1995 |
Indoor air quality and energy performance of air-conditioned office buildings in Singapore. SC Sekhar, KW Tham, KW Cheong Indoor air 13 (4), 315-331, 2003 | 76 | 2003 |
Indoor air quality and thermal comfort studies of an under-floor air-conditioning system in the tropics SC Sekhar, CS Ching Energy and Buildings 34 (5), 431-444, 2002 | 73 | 2002 |
Thermal comfort in air‐conditioned buildings in hot and humid climates–why are we not getting it right? SC Sekhar Indoor air 26 (1), 138-152, 2016 | 72 | 2016 |
Local thermal sensation and comfort study in a field environment chamber served by displacement ventilation system in the tropics KWD Cheong, WJ Yu, SC Sekhar, KW Tham, R Kosonen Building and Environment 42 (2), 525-533, 2007 | 69 | 2007 |
Thermal comfort and IAQ characteristics of naturally/mechanically ventilated and air-conditioned bedrooms in a hot and humid climate SC Sekhar, SE Goh Building and Environment 46 (10), 1905-1916, 2011 | 68 | 2011 |
Ceiling‐mounted personalized ventilation system integrated with a secondary air distribution system–a human response study in hot and humid climate B Yang, SC Sekhar, AK Melikov Indoor Air 20 (4), 309-319, 2010 | 64 | 2010 |
Impact of airflow profile on indoor air quality—a tropical study SC Sekhar, HC Willem Building and Environment 39 (3), 255-266, 2004 | 54 | 2004 |
A critical evaluation of variable air volume system in hot and humid climates SC Sekhar Energy and Buildings 26 (2), 223-232, 1997 | 48 | 1997 |
Temperature and ventilation effects on the work performance of office workers (study of a call center in the tropics) KW Tham, HC Willem, SC Sekhar, DP Wyon, P Wargocki, PO Fanger Proceedings of healthy buildings 3, 280-286, 2003 | 42 | 2003 |
Assessment of thermal environment using a thermal manikin in a field environment chamber served by displacement ventilation system KWD Cheong, WJ Yu, R Kosonen, KW Tham, SC Sekhar Building and environment 41 (12), 1661-1670, 2006 | 39 | 2006 |