Stephen P Morgan
Stephen P Morgan
Professor of Biomedical Engineering, University of Nottingham
Verified email at nottingham.ac.uk - Homepage
TitleCited byYear
Surface-reflection elimination in polarization imaging of superficial tissue
SP Morgan, IM Stockford
Optics letters 28 (2), 114-116, 2003
2182003
Effects of polarization state and scatterer concentration on optical imaging through scattering media
SP Morgan, MP Khong, MG Somekh
Applied optics 36 (7), 1560-1565, 1997
1681997
Application of region-based segmentation and neural network edge detection to skin lesions
MI Rajab, MS Woolfson, SP Morgan
Computerized Medical Imaging and Graphics 28 (1-2), 61-68, 2004
1422004
Goodpasture's disease in the absence of circulating anti-glomerular basement membrane antibodies as detected by standard techniques
AD Salama, T Dougan, JB Levy, HT Cook, SH Morgan, S Naudeer, ...
American journal of kidney diseases 39 (6), 1162-1167, 2002
1422002
A user-centred approach to requirements elicitation in medical device development: A case study from an industry perspective
JL Martin, DJ Clark, SP Morgan, JA Crowe, E Murphy
Applied ergonomics 43 (1), 184-190, 2012
1112012
Polarization properties of light backscattered from a two layer scattering medium
SP Morgan, ME Ridgway
Optics Express 7 (12), 395-402, 2000
932000
User needs elicitation via analytic hierarchy process (AHP). A case study on a Computed Tomography (CT) scanner
L Pecchia, JL Martin, A Ragozzino, C Vanzanella, A Scognamiglio, ...
BMC medical informatics and decision making 13 (1), 2, 2013
902013
Cracking processes in Barre granite: fracture process zones and crack coalescence
SP Morgan, CA Johnson, HH Einstein
International Journal of Fracture 180 (2), 177-204, 2013
732013
Analysis of the spatial distribution of polarized light backscattered from layered scattering media
IM Stockford, SP Morgan, PCY Chang, JG Walker
Journal of Biomedical Optics 7 (3), 313-320, 2002
502002
Highly sensitive optical fibre long period grating biosensor anchored with silica core gold shell nanoparticles
L Marques, FU Hernandez, SW James, SP Morgan, M Clark, RP Tatam, ...
Biosensors and Bioelectronics 75, 222-231, 2016
482016
Longitudinal acoustic properties of poly (lactic acid) and poly (lactic-co-glycolic acid)
NG Parker, ML Mather, SP Morgan, MJW Povey
Biomedical Materials 5 (5), 055004, 2010
422010
Image-based characterization of foamed polymeric tissue scaffolds
ML Mather, SP Morgan, LJ White, H Tai, W Kockenberger, SM Howdle, ...
Biomedical materials 3 (1), 015011, 2008
392008
Meeting the needs of monitoring in tissue engineering
ML Mather, SP Morgan, JA Crowe
Future Medicine Ltd 2 (2), 145-160, 2007
342007
Evaluation of a novel ultra small target technology supporting on-product overlay measurements
HJH Smilde, A den Boef, M Kubis, M Jak, M van Schijndel, A Fuchs, ...
Metrology, Inspection, and Process Control for Microlithography XXVI 8324 …, 2012
332012
Biomedical application of optical fibre sensors
R Correia, S James, SW Lee, SP Morgan, S Korposh
Journal of Optics 20 (7), 073003, 2018
302018
Nanoscale Ultrasound‐Switchable FRET‐Based Liposomes for Near‐Infrared Fluorescence Imaging in Optically Turbid Media
Q Zhang, SP Morgan, ML Mather
Small 13 (33), 1602895, 2017
282017
Controlling the phase response of a diffusive wave phased array system
SP Morgan, KY Yong
Optics express 7 (13), 540-546, 2000
282000
Ultrasound modulated imaging of luminescence generated within a scattering medium
NT Huynh, BR Hayes-Gill, F Zhang, SP Morgan
Journal of biomedical optics 18 (2), 020505, 2013
272013
Method and apparatus for determining an overlay error
AJ Den Boef, M van der Schaar, A Fuchs, MJ Coogans, K Bhattacharyya, ...
US Patent 8,908,147, 2014
262014
Highly sensitive volatile organic compounds vapour measurements using a long period grating optical fibre sensor coated with metal organic framework ZIF-8
J Hromadka, B Tokay, R Correia, SP Morgan, S Korposh
Sensors and Actuators B: Chemical 260, 685-692, 2018
232018
The system can't perform the operation now. Try again later.
Articles 1–20