Follow
António Ramos
Title
Cited by
Cited by
Year
Tetrahedral versus hexahedral finite elements in numerical modelling of the proximal femur
A Ramos, JA Simões
Medical engineering & physics 28 (9), 916-924, 2006
2742006
Medical devices biomaterials – A review
AJ Festas, A Ramos, JP Davim
Proceedings of the Institution of Mechanical Engineers, Part L: Journal of …, 2020
1462020
Study of biochemical and microbiological parameters during composting of pine and eucalyptus bark
AC Cunha-Queda, HM Ribeiro, A Ramos, F Cabral
Bioresource technology 98 (17), 3213-3220, 2007
1352007
The influence of finishing milling strategies on texture, roughness and dimensional deviations on the machining of complex surfaces
AM Ramos, C Relvas, JA Simoes
Journal of Materials Processing Technology 136 (1-3), 209-216, 2003
1192003
Straight, semi-anatomic and anatomic TMJ implants: the influence of condylar geometry and bone fixation screws
A Ramos, A Completo, C Relvas, M Mesnard, JA Simões
Journal of Cranio-Maxillofacial Surgery 39 (5), 343-350, 2011
842011
Biomechanical analysis comparing natural and alloplastic temporomandibular joint replacement using a finite element model
M Mesnard, A Ramos, A Ballu, J Morlier, M Cid, JA Simoes
Journal of Oral and Maxillofacial Surgery 69 (4), 1008-1017, 2011
782011
Double permanent magnet vibration power generator for smart hip prosthesis
R Morais, NM Silva, PM Santos, CM Frias, JAF Ferreira, AM Ramos, ...
Sensors and Actuators A: Physical 172 (1), 259-268, 2011
752011
The influence of cement mantle thickness and stem geometry on fatigue damage in two different cemented hip femoral prostheses
A Ramos, JA Simões
Journal of biomechanics 42 (15), 2602-2610, 2009
642009
Plated and intact femur strains in fracture fixation using fiber Bragg gratings and strain gauges
PM Talaia, A Ramos, I Abe, MW Schiller, P Lopes, RN Nogueira, JL Pinto, ...
Experimental mechanics 47, 355-363, 2007
592007
Stress analysis of temporomandibular joint disc during maintained clenching using a viscohyperelastic finite element model
M Aoun, M Mesnard, L Monède-Hocquard, A Ramos
Journal of Oral and Maxillofacial Surgery 72 (6), 1070-1077, 2014
582014
Numerical and experimental models of the mandible
A Ramos, A Ballu, M Mesnard, P Talaia, JA Simões
Experimental Mechanics 51, 1053-1059, 2011
572011
Fiber optic intensity-modulated sensors: A review in biomechanics
P Roriz, A Ramos, JL Santos, JA Simões
Photonic Sensors 2, 315-330, 2012
552012
Biomechanical evaluation of proximal tibia behaviour with the use of femoral stems in revision TKA: an in vitro and finite element analysis
A Completo, A Rego, F Fonseca, A Ramos, C Relvas, JA Simões
Clinical biomechanics 25 (2), 159-165, 2010
502010
Design process of a novel cemented hip femoral stem concept
A Ramos, A Completo, C Relvas, JA Simoes
Materials & Design 33, 313-321, 2012
422012
New cosurface capacitive stimulators for the development of active osseointegrative implantable devices
MP Soares dos Santos, A Marote, T Santos, J Torrão, A Ramos, ...
Scientific reports 6 (1), 30231, 2016
412016
Instrumented hip implants: Electric supply systems
MPS dos Santos, JAF Ferreira, A Ramos, JAO Simões, R Morais, ...
Journal of biomechanics 46 (15), 2561-2571, 2013
412013
Machining of titanium alloys for medical application-a review
A Festas, A Ramos, JP Davim
Proceedings of the Institution of Mechanical Engineers, Part B: Journal of …, 2022
382022
Capacitive technologies for highly controlled and personalized electrical stimulation by implantable biomedical systems
MP Soares dos Santos, J Coutinho, A Marote, B Sousa, A Ramos, ...
Scientific Reports 9 (1), 5001, 2019
342019
Effect of occlusal splints on the stress distribution on the temporomandibular joint disc
FM Ferreira, P Cézar, CJ Soares, AMAM Ramos, AJ Fernandes-Neto
Brazilian Dental Journal 28, 324-329, 2017
342017
Biomechanical evaluation of different reconstructive techniques of proximal tibia in revision total knee arthroplasty: An in-vitro and finite element analysis
A Completo, R Duarte, F Fonseca, JA Simões, A Ramos, C Relvas
Clinical Biomechanics 28 (3), 291-298, 2013
342013
The system can't perform the operation now. Try again later.