Follow
Bilal Qureshi
Title
Cited by
Cited by
Year
A complete model of wet cooling towers with fouling in fills
BA Qureshi, SM Zubair
Applied thermal engineering 26 (16), 1982-1989, 2006
1132006
A comprehensive design and performance evaluation study of counter flow wet cooling towers
BA Qureshi, SM Zubair
International Journal of Refrigeration 27 (8), 914-923, 2004
1082004
Second-law-based performance evaluation of cooling towers and evaporative heat exchangers
BA Qureshi, SM Zubair
International journal of thermal sciences 46 (2), 188-198, 2007
922007
A comprehensive design and rating study of evaporative coolers and condensers. Part I. Performance evaluation
BA Qureshi, SM Zubair
International journal of refrigeration 29 (4), 645-658, 2006
902006
Experimental energetic analysis of a vapor compression refrigeration system with dedicated mechanical sub-cooling
BA Qureshi, M Inam, MA Antar, SM Zubair
Applied Energy 102, 1035-1041, 2013
852013
The effect of refrigerant combinations on performance of a vapor compression refrigeration system with dedicated mechanical sub-cooling
BA Qureshi, SM Zubair
International Journal of Refrigeration 35 (1), 47-57, 2012
822012
Mechanical sub-cooling vapor compression systems: Current status and future directions
BA Qureshi, SM Zubair
International Journal of Refrigeration 36 (8), 2097-2110, 2013
682013
Modeling of droplet entrainment in co-current annular two-phase flow: A new approach
A Al-Sarkhi, C Sarica, B Qureshi
International Journal of Multiphase Flow, 2011
672011
Application of exergy analysis to various psychrometric processes
BA Qureshi, SM Zubair
International journal of energy research 27 (12), 1079-1094, 2003
672003
Performance degradation of a vapor compression refrigeration system under fouled conditions
BA Qureshi, SM Zubair
International Journal of Refrigeration 34 (4), 1016-1027, 2011
582011
The impact of fouling on performance of a vapor compression refrigeration system with integrated mechanical sub-cooling system
BA Qureshi, SM Zubair
Applied Energy 92, 750-762, 2012
552012
The impact of fouling on the condenser of a vapor compression refrigeration system: An experimental observation
BA Qureshi, SM Zubair
International Journal of Refrigeration 38, 260-266, 2014
532014
The impact of fouling on performance evaluation of evaporative coolers and condensers
BA Qureshi, SM Zubair
International journal of energy research 29 (14), 1313-1330, 2005
522005
A Comprehensive Review of Saline Water Correlations and Data: Part II—Thermophysical Properties
NAA Qasem, MM Generous, BA Qureshi, SM Zubair
Arabian Journal for Science and Engineering, 1-39, 2021
482021
Prediction of evaporation losses in wet cooling towers
BA Qureshi, SM Zubair
Heat transfer engineering 27 (9), 86-92, 2006
472006
Exergetic analysis of a brackish water reverse osmosis desalination unit with various energy recovery systems
BA Qureshi, SM Zubair
Energy 93, 256-265, 2015
462015
A comprehensive design and rating study of evaporative coolers and condensers. Part II. Sensitivity analysis
BA Qureshi, SM Zubair
International journal of refrigeration 29 (4), 659-668, 2006
452006
Design and performance evaluation of reverse osmosis desalination systems: An emphasis on fouling modeling
BA Qureshi, SM Zubair, AK Sheikh, A Bhujle, S Dubowsky
Applied Thermal Engineering 60 (1), 208-217, 2013
412013
Improvement in design of electrodialysis desalination plants by considering the Donnan potential
NAA Qasem, BA Qureshi, SM Zubair
Desalination 441, 62-76, 2018
402018
Exergo-economic analysis of a seawater reverse osmosis desalination plant with various retrofit options
MA Jamil, BA Qureshi, SM Zubair
Desalination 401, 88-98, 2017
402017
The system can't perform the operation now. Try again later.
Articles 1–20