Peter B Greer
Peter B Greer
Verified email at newcastle.edu.au
TitleCited byYear
Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapy
PB Greer, CC Popescu
Medical physics 30 (7), 1618-1627, 2003
2742003
An atlas-based electron density mapping method for magnetic resonance imaging (MRI)-alone treatment planning and adaptive MRI-based prostate radiation therapy
JA Dowling, J Lambert, J Parker, O Salvado, J Fripp, A Capp, C Wratten, ...
International Journal of Radiation Oncology* Biology* Physics 83 (1), e5-e11, 2012
2172012
Cone beam computerized tomography: the effect of calibration of the Hounsfield unit number to electron density on dose calculation accuracy for adaptive radiation therapy
J Hatton, B McCurdy, PB Greer
Physics in Medicine & Biology 54 (15), N329, 2009
1392009
MRI-guided prostate radiation therapy planning: Investigation of dosimetric accuracy of MRI-based dose planning
J Lambert, PB Greer, F Menk, J Patterson, J Parker, K Dahl, S Gupta, ...
Radiotherapy and Oncology 98 (3), 330-334, 2011
1252011
Correction of pixel sensitivity variation and off‐axis response for amorphous silicon EPID dosimetry
PB Greer
Medical physics 32 (12), 3558-3568, 2005
1252005
Evaluation of an algorithm for the assessment of the MTF using an edge method
PB Greer, T Van Doorn
Medical Physics 27 (9), 2048-2059, 2000
1242000
Time to biochemical failure and prostate-specific antigen doubling time as surrogates for prostate cancer-specific mortality: evidence from the TROG 96.01 randomised controlled …
JW Denham, A Steigler, C Wilcox, DS Lamb, D Joseph, C Atkinson, ...
The Lancet Oncology 9 (11), 1058-1068, 2008
882008
Dosimetric properties of an amorphous‐silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT
BMC McCurdy, PB Greer
Medical physics 36 (7), 3028-3039, 2009
852009
Does the planning dose–volume histogram represent treatment doses in image-guided prostate radiation therapy? Assessment with cone-beam computerised tomography scans
JA Hatton, PB Greer, C Tang, P Wright, A Capp, S Gupta, J Parker, ...
Radiotherapy and Oncology 98 (2), 162-168, 2011
682011
Experimental investigation of the response of an amorphous silicon EPID to intensity modulated radiotherapy beams
PB Greer, P Vial, L Oliver, C Baldock
Medical physics 34 (11), 4389-4398, 2007
652007
Automatic substitute computed tomography generation and contouring for magnetic resonance imaging (MRI)-alone external beam radiation therapy from standard MRI sequences
JA Dowling, J Sun, P Pichler, D Rivest-Hénault, S Ghose, H Richardson, ...
International Journal of Radiation Oncology* Biology* Physics 93 (5), 1144-1153, 2015
602015
Measurement and modeling of the effect of support arm backscatter on dosimetry with a Varian EPID
P Rowshanfarzad, BMC McCurdy, M Sabet, C Lee, DJ O'Connor, ...
Medical physics 37 (5), 2269-2278, 2010
602010
Patient specific prostate segmentation in 3-D magnetic resonance images
SS Chandra, JA Dowling, KK Shen, P Raniga, JPW Pluim, PB Greer, ...
IEEE transactions on medical imaging 31 (10), 1955-1964, 2012
572012
The impact of MLC transmitted radiation on EPID dosimetry for dynamic MLC beams
P Vial, PB Greer, P Hunt, L Oliver, C Baldock
Medical physics 35 (4), 1267-1277, 2008
572008
Detection and correction for EPID and gantry sag during arc delivery using cine EPID imaging
P Rowshanfarzad, M Sabet, DJ O'Connor, PM McCowan, BMC McCurdy, ...
Medical physics 39 (2), 623-635, 2012
542012
EPID‐based verification of the MLC performance for dynamic IMRT and VMAT
P Rowshanfarzad, M Sabet, MP Barnes, DJ O'Connor, PB Greer
Medical physics 39 (10), 6192-6207, 2012
512012
Comparison of two methods for anterior–posterior isocenter localization in pelvic radiotherapy using electronic portal imaging
PB Greer, TM Mortensen, CC Jose
International Journal of Radiation Oncology* Biology* Physics 41 (5), 1193-1199, 1998
511998
Fast automatic multi-atlas segmentation of the prostate from 3D MR images
JA Dowling, J Fripp, S Chandra, JPW Pluim, J Lambert, J Parker, ...
International Workshop on Prostate Cancer Imaging, 10-21, 2011
502011
Off‐axis dose response characteristics of an amorphous silicon electronic portal imaging device
PB Greer
Medical physics 34 (10), 3815-3824, 2007
472007
Isocenter verification for linac‐based stereotactic radiation therapy: review of principles and techniques
P Rowshanfarzad, M Sabet, DJ O'connor, PB Greer
Journal of applied clinical medical physics 12 (4), 185-195, 2011
462011
The system can't perform the operation now. Try again later.