Enrico Tubaldi
TitleCited byYear
Influence of FPS bearing properties on the seismic performance of base-isolated structures
P Castaldo, E Tubaldi
Earthquake Engineering & Structural Dynamics, 2015
642015
A probabilistic performance-based risk assessment approach for seismic pounding with efficient application to linear systems
E Tubaldi, M Barbato, S Ghazizadeh
Structural Safety 36, 14-22, 2012
462012
Performance-based seismic risk assessment for buildings equipped with linear and nonlinear viscous dampers
E Tubaldi, M Barbato, A Dall’Asta
Engineering Structures 78, 90-99, 2014
452014
A probabilistic performance‐based approach for mitigating the seismic pounding risk between adjacent buildings
M Barbato, E Tubaldi
Earthquake Engineering & Structural Dynamics 42 (8), 1203-1219, 2013
412013
Probabilistic seismic response assessment of linear systems equipped with nonlinear viscous dampers
E Tubaldi, L Ragni, A Dall'Asta
Earthquake Engineering & Structural Dynamics 44 (1), 101-120, 2015
402015
Probabilistic performance assessment of low‐ductility reinforced concrete frames retrofitted with dissipative braces
F Freddi, E Tubaldi, L Ragni, A Dall'Asta
Earthquake Engineering & Structural Dynamics 42 (7), 993-1011, 2013
342013
Influence of model parameter uncertainty on seismic transverse response and vulnerability of steel–concrete composite bridges with dual load path
E Tubaldi, M Barbato, A Dall’Asta
Journal of Structural Engineering 138 (3), 363-374, 2011
342011
Influence of the nonlinear behavior of viscous dampers on the seismic demand hazard of building frames
A Dall′ Asta, E Tubaldi, L Ragni
Earthquake Engineering & Structural Dynamics 45 (1), 149-169, 2016
322016
Nonstationary stochastic response of structural systems equipped with nonlinear viscous dampers under seismic excitation
E Tubaldi, IA Kougioumtzoglou
Earthquake Engineering & Structural Dynamics 44 (1), 121-138, 2015
302015
Dynamic behavior of adjacent buildings connected by linear viscous/viscoelastic dampers
E Tubaldi
Structural Control and Health Monitoring 22 (8), 1086-1102, 2015
292015
New analytical solution of the first-passage reliability problem for linear oscillators
S Ghazizadeh, M Barbato, E Tubaldi
Journal of Engineering Mechanics 138 (6), 695-706, 2011
232011
A parametric study on the axial behaviour of elastomeric isolators in multi-span bridges subjected to horizontal seismic excitations
E Tubaldi, SA Mitoulis, H Ahmadi, A Muhr
Bulletin of Earthquake Engineering 14 (4), 1285-1310, 2016
212016
Influence of ground motion characteristics on the optimal single concave sliding bearing properties for base-isolated structures
P Castaldo, E Tubaldi
Soil Dynamics and Earthquake Engineering 104, 346-364, 2018
182018
Transverse seismic response of continuous steel-concrete composite bridges exhibiting dual load path
E Tubaldi, M Barbato, A Dall'Asta
Earthquakes and Structures 1 (1), 21-41, 2010
182010
Effect of the damper property variability on the seismic reliability of linear systems equipped with viscous dampers
A Dall’Asta, F Scozzese, L Ragni, E Tubaldi
Bulletin of Earthquake Engineering, 1-29, 2017
172017
A design method for seismically isolated bridges with abutment restraint
E Tubaldi, A Dall’Asta
Engineering Structures 33 (3), 786-795, 2011
172011
Probabilistic seismic demand model for pounding risk assessment
E Tubaldi, F Freddi, M Barbato
Earthquake Engineering & Structural Dynamics 45 (11), 1743-1758, 2016
162016
Reliability-based optimal design of nonlinear viscous dampers for the seismic protection of structural systems
D Altieri, E Tubaldi, M De Angelis, E Patelli, A Dall’Asta
Bulletin of Earthquake Engineering 16 (2), 963-982, 2018
152018
Efficient approach for the reliability-based design of linear damping devices for seismic protection of buildings
E Tubaldi, M Barbato, A Dall’Asta
ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part A …, 2015
152015
Transverse free vibrations of continuous bridges with abutment restraint
E Tubaldi, A Dall'Asta
Earthquake Engineering & Structural Dynamics 41 (9), 1319-1340, 2012
132012
The system can't perform the operation now. Try again later.
Articles 1–20