Follow
Robert D. O'Neill
Title
Cited by
Cited by
Year
Microvoltammetric techniques and sensors for monitoring neurochemical dynamics in vivo. A review
RD O'Neill
Analyst 119 (5), 767-779, 1994
2981994
Characterization in vitro and in vivo of the oxygen dependence of an enzyme/polymer biosensor for monitoring brain glucose
BM Dixon, JP Lowry, R D O'Neill
Journal of Neuroscience Methods 119 (2), 135-142, 2002
2382002
Characterization of glucose oxidase-modified poly (phenylenediamine)-coated electrodes in vitro and in vivo: homogeneous interference by ascorbic acid in hydrogen peroxide …
JP Lowry, K McAteer, SS El Atrash, A Duff, RD O'Neill
Analytical Chemistry 66 (10), 1754-1761, 1994
2121994
In vivo voltammetry—present electrodes and methods
CA Marsden, MH Joseph, ZL Kruk, NT Maidment, RD O'Neill, JO Schenk, ...
Neuroscience 25 (2), 389-400, 1988
1591988
Biosensor for neurotransmitter L-glutamic acid designed for efficient use of L-glutamate oxidase and effective rejection of interference
MR Ryan, JP Lowry, RD O’Neill
Analyst 122 (11), 1419-1424, 1997
1531997
Linear sweep voltammetry with carbon paste electrodes in the rat striatum
RD O'Neill, RA Grünewald, M Fillenz, WJ Albery
Neuroscience 7 (8), 1945-1954, 1982
1461982
Comparisons of platinum, gold, palladium and glassy carbon as electrode materials in the design of biosensors for glutamate
R D O’Neill, SC Chang, JP Lowry, CJ McNeil
Biosensors and Bioelectronics 19 (11), 1521-1528, 2004
1422004
Voltammetrically monitored brain ascorbate as an index of excitatory amino acid release in the unrestrained rat
RD O'Neill, M Fillenz, L Sundstrom, JNP Rawlins
Neuroscience letters 52 (3), 227-233, 1984
1321984
Continuous monitoring of extracellular glucose concentrations in the striatum of freely moving rats with an implanted glucose biosensor
JP Lowry, RD O'Neill, MG Boutelle, M Fillenz
Journal of neurochemistry 70 (1), 391-396, 1998
1241998
An amperometric glucose-oxidase/poly (o-phenylenediamine) biosensor for monitoring brain extracellular glucose: in vivo characterisation in the striatum of freely-moving rats
JP Lowry, M Miele, R D O’Neill, MG Boutelle, M Fillenz
Journal of neuroscience methods 79 (1), 65-74, 1998
1201998
Monitoring Brain Chemistry In Vivo: Voltammetric Techniques, Sensors, and Behavioral Applications
RD O'Neill, JP Lowry, M Mas
Critical Reviews™ in Neurobiology 12 (1-2), 1998
1091998
Heterodyads: Electron transfer at a semiconductor electrode-liquid electrolyte interface modified by an adsorbed spacer-acceptor complex
X Marguerettaz, R O'Neill, D Fitzmaurice
Journal of the American Chemical Society 116 (6), 2629-2630, 1994
951994
Simultaneous monitoring of dopamine release in rat frontal cortex, nucleus accumbens and striatum: effect of drugs, circadian changes and correlations with motor activity
RD O'Neill, M Fillenz
Neuroscience 16 (1), 49-55, 1985
951985
Designing sensitive and selective polymer/enzyme composite biosensors for brain monitoring in vivo
RD O’Neill, G Rocchitta, CP McMahon, PA Serra, JP Lowry
TrAC Trends in Analytical Chemistry 27 (1), 78-88, 2008
932008
Control of the oxygen dependence of an implantable polymer/enzyme composite biosensor for glutamate
CP McMahon, G Rocchitta, PA Serra, SM Kirwan, JP Lowry, RD O'Neill
Analytical Chemistry 78 (7), 2352-2359, 2006
882006
Characterization of permselective coatings electrosynthesized on Pt–Ir from the three phenylenediamine isomers for biosensor applications
SJ Killoran, RD O’Neill
Electrochimica Acta 53 (24), 7303-7312, 2008
862008
Partial characterization in vitro of glucose oxidase‐modified poly (phenylenediamine)‐coated electrodes for neurochemical analysis in vivo
JP Lowry, RD O'Neill
Electroanalysis 6 (5‐6), 369-379, 1994
831994
The effect of unilateral cortical lesions on the circadian changes in rat striatal ascorbate and homovanillic acid levels measured in vivo using voltammetry
RD O'Neill, RA Grunewald, M Fillenz, WJ Albery
Neuroscience letters 42 (1), 105-110, 1983
811983
Simultaneous telemetric monitoring of brain glucose and lactate and motion in freely moving rats
G Rocchitta, O Secchi, MD Alvau, D Farina, G Bazzu, G Calia, R Migheli, ...
Analytical chemistry 85 (21), 10282-10288, 2013
802013
Oxygen tolerance of an implantable polymer/enzyme composite glutamate biosensor displaying polycation-enhanced substrate sensitivity
CP McMahon, G Rocchitta, SM Kirwan, SJ Killoran, PA Serra, JP Lowry, ...
Biosensors and Bioelectronics 22 (7), 1466-1473, 2007
802007
The system can't perform the operation now. Try again later.
Articles 1–20