Follow
Hans van Assen
Hans van Assen
SeeCubic BV
Verified email at hvanon.duinhazen.nl
Title
Cited by
Cited by
Year
SPASM: a 3D-ASM for segmentation of sparse and arbitrarily oriented cardiac MRI data
HC Van Assen, MG Danilouchkine, AF Frangi, S Ordás, JJM Westenberg, ...
Medical Image Analysis 10 (2), 286-303, 2006
2722006
Multiplicative calculus in biomedical image analysis
L Florack, H van Assen
Journal of Mathematical Imaging and Vision 42 (1), 64-75, 2012
1842012
Accurate object localization in gray level images using the center of gravity measure: accuracy versus precision
HC van Assen, M Egmont-Petersen, JHC Reiber
IEEE Transactions on Image Processing 11 (12), 1379-1384, 2002
1452002
A 3-D active shape model driven by fuzzy inference: application to cardiac CT and MR
HC Van Assen, MG Danilouchkine, MS Dirksen, JHC Reiber, ...
IEEE Transactions on information technology in biomedicine 12 (5), 595-605, 2008
1022008
Quantification of the temporal evolution of collagen orientation in mechanically conditioned engineered cardiovascular tissues
MP Rubbens, A Driessen-Mol, RA Boerboom, MMJ Koppert, ...
Annals of biomedical engineering 37 (7), 1263-1272, 2009
952009
Cardiac LV segmentation using a 3D active shape model driven by fuzzy inference
HC van Assen, MG Danilouchkine, F Behloul, HJ Lamb, RJ van der Geest, ...
International Conference on Medical Image Computing and Computer-Assisted …, 2003
742003
Vessel diameter measurements in gadolinium contrast-enhanced three-dimensional MRA of peripheral arteries
JJM Westenberg, RJ van der Geest, MNJM Wasser, EL van der Linden, ...
Magnetic resonance imaging 18 (1), 13-22, 2000
722000
Mechanoregulation of vascularization in aligned tissue-engineered muscle: a role for vascular endothelial growth factor
DWJ van der Schaft, ACC van Spreeuwel, HC van Assen, FPT Baaijens
Tissue Engineering Part A 17 (21-22), 2857-2865, 2011
712011
LV challenge LKEB contribution: Fully automated myocardial contour detection
J Wijnhout, D Hendriksen, H Assen, R Der Geest
The MIDAS journal 43, 2, 2009
632009
Phenotyping of Left and Right Ventricular Function in Mouse Models of Compensated Hypertrophy and Heart Failure with Cardiac MRI
BJ van Nierop, HC van Assen, ED van Deel, LBP Niesen, DJ Duncker, ...
PloS one 8 (2), e55424, 2013
452013
Clinical intra-cardiac 4D flow CMR: acquisition, analysis, and clinical applications
A Demirkiran, P van Ooij, JJM Westenberg, MBM Hofman, HC van Assen, ...
European Heart Journal-Cardiovascular Imaging 23 (2), 154-165, 2022
432022
Automatic segmentation of the aortic root in CT angiography of candidate patients for transcatheter aortic valve implantation
MA Elattar, EM Wiegerinck, RN Planken, HC van Assen, J Baan Jr, ...
Medical & Biological Engineering & Computing 52 (7), 611-618, 2014
432014
A novel 3D multi-scale lineness filter for vessel detection
HE Bennink, HC van Assen, GJ Streekstra, R ter Wee, JAE Spaan, ...
International Conference on Medical Image Computing and Computer-Assisted …, 2007
422007
Evolution equations on Gabor transforms and their applications
R Duits, H Führ, B Janssen, M Bruurmijn, L Florack, H van Assen
Applied and Computational Harmonic Analysis 35 (3), 483-526, 2013
412013
Dense multiscale motion extraction from cardiac cine MR tagging using HARP technology
L Florack, H van Assen, A Suinesiaputra
Computer Vision, 2007. ICCV 2007. IEEE 11th International Conference on, 1-8, 2007
342007
Quantification of collagen orientation in 3D engineered tissue
F Daniels, BM ter Haar Romeny, M Rubbens, H Van Assen
3rd Kuala Lumpur International Conference on Biomedical Engineering 2006 …, 2007
342007
Reproducibility of aorta segmentation on 4D flow MRI in healthy volunteers
JF Juffermans, JJM Westenberg, PJ van den Boogaard, AAW Roest, ...
Journal of Magnetic Resonance Imaging 53 (4), 1268-1279, 2021
322021
Optimizing the automatic segmentation of the left ventricle in magnetic resonance images
E Angelie, PJH de Koning, MG Danilouchkine, HC van Assen, G Koning, ...
Medical physics 32 (2), 369-375, 2005
272005
4D flow cardiovascular magnetic resonance derived energetics in the Fontan circulation correlate with exercise capacity and CMR-derived liver fibrosis/congestion
FM Rijnberg, JJM Westenberg, HC van Assen, JF Juffermans, LJM Kroft, ...
Journal of Cardiovascular Magnetic Resonance 24 (1), 21, 2022
232022
Pulmonary blood volume measured by contrast enhanced ultrasound: a comparison with transpulmonary thermodilution
IHF Herold, MAS Hamad, HC van Assen, RA Bouwman, HHM Korsten, ...
British journal of anaesthesia 115 (1), 53-60, 2015
232015
The system can't perform the operation now. Try again later.
Articles 1–20