Wonjun Choi
Wonjun Choi
Institute of Industrial Science, The University of Tokyo
Verified email at iis.u-tokyo.ac.jp - Homepage
Title
Cited by
Cited by
Year
Optimal design of a multi-story double skin facade
J Joe, W Choi, Y Kwak, JH Huh
Energy and Buildings 76, 143-150, 2014
552014
Operation and control strategies for multi-storey double skin facades during the heating season
W Choi, J Joe, Y Kwak, JH Huh
Energy and buildings 49, 454-465, 2012
552012
Effect of natural convection on thermal response test conducted in saturated porous formation: Comparison of gravel-backfilled and cement-grouted borehole heat exchangers
W Choi, R Ooka
Renewable Energy 96, 891-903, 2016
482016
Optimization method for multiple heat source operation including ground source heat pump considering dynamic variation in ground temperature
S Ikeda, W Choi, R Ooka
Applied Energy 193, 466-478, 2017
472017
Interpretation of disturbed data in thermal response tests using the infinite line source model and numerical parameter estimation method
W Choi, R Ooka
Applied Energy 148, 476-488, 2015
472015
Load characteristics and operation strategies of building integrated with multi-story double skin facade
J Joe, W Choi, H Kwon, J Huh
Energy and buildings 60, 185-198, 2013
472013
Exergy analysis of a hybrid ground-source heat pump system
K Menberg, Y Heo, W Choi, R Ooka, R Choudhary, M Shukuya
Applied Energy 204, 31-46, 2017
442017
Bayesian inference for thermal response test parameter estimation and uncertainty assessment
W Choi, H Kikumoto, R Choudhary, R Ooka
Applied Energy 209, 306-321, 2018
322018
Effect of disturbance on thermal response test, part 2: Numerical study of applicability and limitation of infinite line source model for interpretation under disturbance from …
W Choi, R Ooka
Renewable Energy 85, 1090-1105, 2016
302016
Impact of long-term operation of ground-source heat pump on subsurface thermal state in urban areas
W Choi, R Ooka, Y Nam
Sustainable cities and society 38, 429-439, 2018
232018
Effect of disturbance on thermal response test, part 1: Development of disturbance analytical model, parametric study, and sensitivity analysis
W Choi, R Ooka
Renewable Energy 85, 306-318, 2016
222016
Exergy analysis for unsteady-state heat conduction
W Choi, R Ooka, M Shukuya
International Journal of Heat and Mass Transfer 116, 1124-1142, 2018
142018
New perspectives in thermal performance test: Cost-effective apparatus and extended data analysis
W Choi, H Kikumoto, R Ooka
Energy and Buildings 180, 109-121, 2018
92018
Bayesian inference of structural error in inverse models of thermal response tests
W Choi, K Menberg, H Kikumoto, Y Heo, R Choudhary, R Ooka
Applied Energy 228, 1473-1485, 2018
72018
Critical comparison between thermal performance test (TPT) and thermal response test (TRT): Differences in heat transfer process and extractable information
W Choi, H Kikumoto, R Ooka
Energy Conversion and Management 199, 111967, 2019
42019
The effect of natural convection on thermal response test
W Choi, R Ooka
ASHRAE Transactions 120 (2), SE-14-C047, 2014
42014
Experimental and numerical investigation of energy saving potential of centralized and decentralized pumping systems
M Liu, R Ooka, W Choi, S Ikeda
Applied Energy 251, 113359, 2019
32019
Artificial neural network prediction models of stratified thermal energy storage system and borehole heat exchanger for model predictive control
D Lee, R Ooka, S Ikeda, W Choi
Science and Technology for the Built Environment 25 (5), 534-548, 2019
32019
Model predictive control of building energy systems with thermal energy storage in response to occupancy variations and time-variant electricity prices
D Lee, R Ooka, S Ikeda, W Choi, Y Kwak
Energy and Buildings 225, 110291, 2020
22020
Development of physiological human model considering mist wettedness for mist-spraying environments
W Oh, R Ooka, J Nakano, H Kikumoto, O Ogawa, W Choi
Building and Environment 180, 106706, 2020
22020
The system can't perform the operation now. Try again later.
Articles 1–20