Preliminary study of multichannel flexible neural probes coated with hybrid biodegradable polymer Y Kato, I Saito, T Hoshino, T Suzuki, K Mabuchi 2006 International Conference of the IEEE Engineering in Medicine and …, 2006 | 42 | 2006 |
Photosensitive-polyimide based method for fabricating various neural electrode architectures YX Kato, S Furukawa, K Samejima, N Hironaka, M Kashino Frontiers in neuroengineering 5, 11, 2012 | 32 | 2012 |
Improvement of neuronal cell adhesiveness on parylene with oxygen plasma treatment T Hoshino, I Saito, R Kometani, K Samejima, S Matsui, T Suzuki, ... Journal of bioscience and bioengineering 113 (3), 395-398, 2012 | 26 | 2012 |
Development of a BCI master switch based on single-trial detection of contingent negative variation related potentials YX Kato, T Yonemura, K Samejima, T Maeda, H Ando 2011 Annual International Conference of the IEEE Engineering in Medicine and …, 2011 | 21 | 2011 |
Comparison of neuronal cell adhesiveness of materials in the diX (Parylene) family YX Kato, I Saito, H Takano, K Mabuchi, T Hoshino Neuroscience letters 464 (1), 26-28, 2009 | 16 | 2009 |
Flexible intracortical neural probe with biodegradable polymer for delivering bioactive components Y Kato, M Nishino, I Saito, T Suzuki, K Mabuchi 2006 International Conference on Microtechnologies in Medicine and Biology …, 2006 | 15 | 2006 |
Neurite outgrowth of PC12 cells on diX (parylene) family materials T Hoshino, I Saito, H Takano, K Samejima, K Mabuchi, YX Kato Biotechnology progress 28 (2), 587-590, 2012 | 6 | 2012 |
容易かつ廉価な多チャンネル柔軟神経電極の作製法の開発 加藤康広, 牧勝弘, 古川茂人, 柏野牧夫 生体医工学 46 (5), 522-528, 2008 | 3 | 2008 |
A photosensitive polyimide based method for an easy fabrication of multichannel neural electrodes YX Kato, K Maki, S Furukawa, M Kashino 2008 30th Annual International Conference of the IEEE Engineering in …, 2008 | 3 | 2008 |
随伴陰性変動関連電位を利用した脳波スイッチの提案と ROC 解析による評価 加藤康広, 米村朋子, 鮫島和行, 前田太郎, 安藤英由樹 ヒューマンインタフェース学会論文誌 14 (4), 437-444, 2012 | | 2012 |
A preliminary study to develop a BCI switch using contingent negative variation YX Kato, H Teraya, T Yonemura, T Maeda, K Samejima, H Ando Neuroscience Research, e215, 2010 | | 2010 |
Development of a microdialysis probe with multichannel microelectrodes YX Kato, M Kashino, N Hironaka JOURNAL OF PHARMACOLOGICAL SCIENCES 112, 72P-72P, 2010 | | 2010 |
多チャンネル微小電極を有するマイクロダイアリシスプローブの開発 加藤康広, 柏野牧夫, 廣中直行 電気学会論文誌 C (電子・情報・システム部門誌) 129 (12), 2189-2193, 2009 | | 2009 |
Development of a Microdialysis Probe with Multichannel Microelectrodes YX Kato, M Kashino, N Hironaka ITEIS 129 (12), 2189-2193, 2009 | | 2009 |
ラット聴皮質からの多チャンネル誘発電位計測に向けた表面電極の開発 加藤康広, 牧勝弘, 古川茂人 聴覚研究会資料= Proceedings of the auditory research meeting 38 (7), 723-726, 2008 | | 2008 |
Development of surface microelectrode array based on photosensitive polyimide for recording from the auditory cortex YX Kato, K Maki, S Furukawa, M Kashino NEUROSCIENCE RESEARCH 61, S178-S178, 2008 | | 2008 |
生分解性ポリマーを用いた薬剤徐放型柔軟神経プローブの開発 加藤康広, 鈴木隆文, 満渕邦彦 電気学会研究会資料. MBE, 医用・生体工学研究会 2006 (1), 85-89, 2006 | | 2006 |