A practical guide to image processing in the creation of 3D models for orthopedics N Green, V Glatt, K Tetsworth, LJ Wilson, CA Grant Techniques in Orthopaedics 31 (3), 153-163, 2016 | 43 | 2016 |
Shear properties of bilaminar polymethylmethacrylate cement mantles in revision hip joint arthroplasty PC Weinrauch, C Bell, L Wilson, B Goss, C Lutton, RW Crawford The Journal of arthroplasty 22 (3), 394-403, 2007 | 43 | 2007 |
Biomechanical evaluation of double K rackow sutures versus the three‐loop pulley suture in a canine gastrocnemius tendon avulsion model L Wilson, TA Banks, P Luckman, B Smith Australian veterinary journal 92 (11), 427-432, 2014 | 40 | 2014 |
Periprosthetic fracture torque for short versus standard cemented hip stems: an experimental in vitro study T Morishima, BL Ginsel, GGH Choy, LJ Wilson, SL Whitehouse, ... The Journal of arthroplasty 29 (5), 1067-1071, 2014 | 39 | 2014 |
Cement-in-cement revision for selected Vancouver Type B1 femoral periprosthetic fractures: a biomechanical analysis CJ Brew, LJ Wilson, SL Whitehouse, MJW Hubble, RW Crawford The Journal of Arthroplasty 28 (3), 521-525, 2013 | 21 | 2013 |
Can larger-bodied cemented femoral components reduce periprosthetic fractures? A biomechanical study BL Ginsel, T Morishima, LJ Wilson, SL Whitehouse, RW Crawford Archives of orthopaedic and trauma surgery 135, 517-522, 2015 | 20 | 2015 |
Inferior epigastric artery avulsion: a fracture table complication FS Haddad, CE Cobiella, L Wilson Journal of orthopaedic trauma 12 (8), 587-588, 1998 | 20 | 1998 |
Standardized anthropological measurement of postcranial bones using three-dimensional models in CAD software MS Reynolds, DM MacGregor, MD Barry, N Lottering, B Schmutz, ... Forensic science international 278, 381-387, 2017 | 19 | 2017 |
Comparison of mechanical and ultrasound elastic modulus of ovine tibial cortical bone CA Grant, LJ Wilson, C Langton, D Epari Medical engineering & physics 36 (7), 869-874, 2014 | 18 | 2014 |
Low cost polymer intramedullary nails for fracture fixation: a biomechanical study in a porcine femur model D Lewis, C Lutton, LJ Wilson, RW Crawford, B Goss Archives of orthopaedic and trauma surgery 129, 817-822, 2009 | 17 | 2009 |
In vitro cyclic testing of the Exeter stem after cement within cement revision LJ Wilson, CGR Bell, P Weinrauch, R Crawford The Journal of Arthroplasty 24 (5), 789-794, 2009 | 16 | 2009 |
Shortening cemented femoral implants: an in vitro investigation to quantify exeter femoral implant rotational stability vs simulated implant length LJ Wilson, JA Roe, MJ Pearcy, RW Crawford The Journal of Arthroplasty 27 (6), 934-939, 2012 | 14 | 2012 |
Risk of periprosthetic femur fracture after anterior cortical bone windowing: a mechanical analysis of short versus long cemented stems in pigs LJ Wilson, CJ Richards, D Irvine, A Tillie, RW Crawford Acta orthopaedica 82 (6), 674-678, 2011 | 13 | 2011 |
Performance measurements of rail curve lubricants LJ Wilson Queensland University of Technology, 2006 | 11 | 2006 |
Repair of sacral fractures using pins and polymethylmethacrylate (six cases) L Wilson Australian Veterinary Journal 93 (9), 311-318, 2015 | 8 | 2015 |
Do split paediatric forearm POP casts need to be completed? A biomechanical study N Patel, L Wilson, G Wansbrough Injury 46 (7), 1231-1237, 2015 | 8 | 2015 |
Author reply: cement-in-cement revision for selected Vancouver type b1 femoral periprosthetic fractures: a biomechanical analysis R Crawford, S Whitehouse, C Brew, L Wilson, M Hubble Journal of Arthroplasty 28 (8), 1446-1447, 2013 | 5 | 2013 |
Is softcast (3M) strong enough for potentially unstable paediatric forearm fractures? N Patel, L Wilson, G Wansbrough Injury 47 (10), 2258-2265, 2016 | 2 | 2016 |
Patella Fracture Repair Using Multiple Fixation Modalities in a Dog L Chau, L Wilson VCOT Open 4 (01), e5-e11, 2021 | 1 | 2021 |
Does cutting a plaster window weaken its strength? N Patel, L Wilson, G Wansbrough Injury 48 (3), 648-652, 2017 | 1 | 2017 |